Evidence map›Paper›PMID 36904859›Full record

ArticleSensors (Basel, Switzerland)2023

A Novel Transformer-Based IMU Self-Calibration Approach through On-Board RGB Camera for UAV Flight Stabilization.

Danilo Avola, Luigi Cinque, Gian Luca Foresti, Romeo Lanzino, Marco Raoul Marini, Alessio Mecca, Francesco Scarcello

Full text read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Danilo AvolaDepartment of Computer Science, Sapienza University, Via Salaria 113, 00198 Rome, Italy.ORCID 0000-0001-9437-6217
Luigi CinqueDepartment of Computer Science, Sapienza University, Via Salaria 113, 00198 Rome, Italy.ORCID 0000-0001-9149-2175
Gian Luca ForestiDepartment of Mathematics, Computer Science and Physics, University of Udine, Via delle Scienze 206, 33100 Udine, Italy.ORCID 0000-0002-8425-6892
Romeo LanzinoDepartment of Computer Science, Sapienza University, Via Salaria 113, 00198 Rome, Italy.ORCID 0000-0003-2939-3007
Marco Raoul MariniDepartment of Computer Science, Sapienza University, Via Salaria 113, 00198 Rome, Italy.ORCID 0000-0002-2540-2570
Alessio MeccaDepartment of Mathematics, Computer Science and Physics, University of Udine, Via delle Scienze 206, 33100 Udine, Italy.ORCID 0000-0002-1370-8759
Francesco ScarcelloDepartment of Computer Engineering, Modeling, Electronics and Systems Engineering, University of Calabria, Via Pietro Bucci, 87036 Rende, Italy.ORCID 0000-0001-7765-1563

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

During flight, unmanned aerial vehicles (UAVs) need several sensors to follow a predefined path and reach a specific destination. To this aim, they generally exploit an inertial measurement unit (IMU) for pose estimation. Usually, in the UAV context, an IMU entails a three-axis accelerometer and a three-axis gyroscope. However, as happens for many physical devices, they can present some misalignment between the real value and the registered one. These systematic or occasional errors can derive from different sources and could be related to the sensor itself or to external noise due to the place where it is located. Hardware calibration requires special equipment, which is not always available. In any case, even if possible, it can be used to solve the physical problem and sometimes requires removing the sensor from its location, which is not always feasible. At the same time, solving the problem of external noise usually requires software procedures. Moreover, as reported in the literature, even two IMUs from the same brand and the same production chain could produce different measurements under identical conditions. This paper proposes a soft calibration procedure to reduce the misalignment created by systematic errors and noise based on the grayscale or RGB camera built-in on the drone. Based on the transformer neural network architecture trained in a supervised learning fashion on pairs of short videos shot by the UAV's camera and the correspondent UAV measurements, the strategy does not require any special equipment. It is easily reproducible and could be used to increase the trajectory accuracy of the UAV during the flight.

Indexed as

computer visiondeep learningIMUIMU calibrationtransformerUAV

Identifiers

PMID36904859
PMCPMC10007070

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read12
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.