Comparison between Two Time Synchronization and Data Alignment Methods for Multi-Channel Wearable Biosensor Systems Using BLE Protocol.

He Wang, Jianan Li, Benjamin E McDonald, Todd R Farrell, Xinming Huang, Edward A Clancy

Full text read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

He WangWorcester Polytechnic Institute, Worcester, MA 01609, USA.
Jianan LiWorcester Polytechnic Institute, Worcester, MA 01609, USA.
Benjamin E McDonaldLiberating Technologies, Inc. (LTI), Holliston, MA 01746, USA.ORCID 0000-0001-8657-4213
Todd R FarrellLiberating Technologies, Inc. (LTI), Holliston, MA 01746, USA.ORCID 0000-0002-2811-200X
Xinming HuangWorcester Polytechnic Institute, Worcester, MA 01609, USA.ORCID 0000-0003-0584-3448
Edward A ClancyWorcester Polytechnic Institute, Worcester, MA 01609, USA.ORCID 0000-0002-0729-2523

Funding

US Army Medical Research and Materiel Command W81XWH-18-C-0111
6 · The paper itself

Abstract

Wireless wearable sensor systems for biomedical signal acquisition have developed rapidly in recent years. Multiple sensors are often deployed for monitoring common bioelectric signals, such as EEG (electroencephalogram), ECG (electrocardiogram), and EMG (electromyogram). Compared with ZigBee and low-power Wi-Fi, Bluetooth Low Energy (BLE) can be a more suitable wireless protocol for such systems. However, current time synchronization methods for BLE multi-channel systems, via either BLE beacon transmissions or additional hardware, cannot satisfy the requirements of high throughput with low latency, transferability between commercial devices, and low energy consumption. We developed a time synchronization and simple data alignment (SDA) algorithm, which was implemented in the BLE application layer without the need for additional hardware. We further developed a linear interpolation data alignment (LIDA) algorithm to improve upon SDA. We tested our algorithms using sinusoidal input signals at different frequencies (10 to 210 Hz in increments of 20 Hz-frequencies spanning much of the relevant range of EEG, ECG, and EMG signals) on Texas Instruments (TI) CC26XX family devices, with two peripheral nodes communicating with one central node. The analysis was performed offline. The lowest average (±standard deviation) absolute time alignment error between the two peripheral nodes achieved by the SDA algorithm was 384.3 ± 386.5 μs, while that of the LIDA algorithm was 189.9 ± 204.7 μs. For all sinusoidal frequencies tested, the performance of LIDA was always statistically better than that of SDA. These average alignment errors were quite low-well below one sample period for commonly acquired bioelectric signals.

Indexed as

Biosensing TechniquesWearable Electronic DevicesAcetanilidesAcetatesAlgorithmsWireless TechnologyAcetanilidesAcetatesLIDAbiomedical signalbiosensorBLE (Bluetooth Low Energy)time synchronizationwireless sensor network

Identifiers

PMID36904670
PMCPMC10007376

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read17
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.