Evidence map›Paper›PMID 36902557›Full record

ArticleJournal of clinical medicine2023

Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing.

Stefan Förch, Sabrina Sandriesser, Christian von Rüden, Edgar Mayr, Peter Augat

Full text read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Biomechanical evaluation of cerclage wiring in plated tibia fractures using human and synthetic specimens.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Stefan FörchDepartment of Trauma, Orthopaedic, Plastic and Hand Surgery, University Hospital of Augsburg, Stenglinstrasse 2, 86156 Augsburg, Germany.
Sabrina SandriesserInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany.
Christian von RüdenInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany.ORCID 0000-0001-6308-8378
Edgar MayrDepartment of Trauma, Orthopaedic, Plastic and Hand Surgery, University Hospital of Augsburg, Stenglinstrasse 2, 86156 Augsburg, Germany.
Peter AugatInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPartial weight-bearing after operatively treated fractures has been the standard of care over the past decades. Recent studies report on better rehabilitation and faster return to daily life in case of immediate weight-bearing as tolerated. To allow early weight-bearing, osteosynthesis needs to provide sufficient mechanical stability. The purpose of this study was to investigate the stabilizing benefits of additive cerclage wiring in combination with intramedullary nailing of distal tibia fractures.

methodsIn 14 synthetic tibiae, a reproducible distal spiral fracture was treated by intramedullary nailing. In half of the samples, the fracture was further stabilized by additional cerclage wiring. Under clinically relevant partial and full weight-bearing loads the samples were biomechanically tested and axial construct stiffness as well as interfragmentary movements were assessed. Subsequently, a 5 mm fracture gap was created to simulate insufficient reduction, and tests were repeated.

resultsIntramedullary nails offer already high axial stability. Thus, axial construct stiffness cannot be significantly enhanced by an additive cerclage (2858 ± 958 N/mm NailOnly vs. 3727 ± 793 N/mm Nail + Cable;

conclusionsIn well-reduced spiral fractures of the distal tibia, the construct stability of intramedullary nailing can be further increased by additional cerclage wiring. From a biomechanical point of view, augmentation of the primary implant reduced shear movement sufficiently to allow immediate weight-bearing as tolerated. Especially, elderly patients would benefit from early post-operative mobilization, which allows for accelerated rehabilitation and a faster return to daily activities.

Indexed as

biomechanicscablecerclagecomminuted fractureintramedullary nailingtibia shaft

Identifiers

PMID36902557
PMCPMC10002559

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read17
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.