Evidence map›Paper›PMID 36900351›Full record

ArticleCancers2023

Field and Temperature Shaping for Microwave Hyperthermia: Recent Treatment Planning Tools to Enhance SAR-Based Procedures.

Martina T Bevacqua, Rossella Gaffoglio, Gennaro G Bellizzi, Marco Righero, Giorgio Giordanengo, Lorenzo Crocco, Giuseppe Vecchi, Tommaso Isernia

Full text read
In one paragraph

Article in Cancers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. GdRSC advances · 2025
    Article
  3. Validation of the implementation of phased-array heating systems in Plan2Heat.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Martina T BevacquaDepartment of Information Engineering, Infrastructures and Sustainable Energy, Università Mediterranea di Reggio Calabria, Via Graziella, 89124 Reggio di Calabria, Italy.ORCID 0000-0001-6557-1283
Rossella GaffoglioAdvanced Computing, Photonics & Electromagnetics (CPE), Fondazione LINKS, 10138 Turin, Italy.
Gennaro G BellizziDepartment of Information Engineering, Infrastructures and Sustainable Energy, Università Mediterranea di Reggio Calabria, Via Graziella, 89124 Reggio di Calabria, Italy.ORCID 0000-0003-2866-2973
Marco RigheroAdvanced Computing, Photonics & Electromagnetics (CPE), Fondazione LINKS, 10138 Turin, Italy.
Giorgio GiordanengoAdvanced Computing, Photonics & Electromagnetics (CPE), Fondazione LINKS, 10138 Turin, Italy.ORCID 0000-0002-3823-6452
Lorenzo CroccoNational Research Council of Italy (CNR), Istituto per il Rilevamento Elettromagnetico dell' Ambiente, CNR-IREA, Via Diocleziano 308, 80100 Napoli, Italy.ORCID 0000-0003-2498-3219
Giuseppe VecchiDepartment of Electronics and Telecommunications, Politecnico di Torino, 10129 Turin, Italy.ORCID 0000-0003-0798-5431
Tommaso IserniaDepartment of Information Engineering, Infrastructures and Sustainable Energy, Università Mediterranea di Reggio Calabria, Via Graziella, 89124 Reggio di Calabria, Italy.

Funding

Ministry of Education, Universities and Research PRIN 2015KJE87K_001
6 · The paper itself

Abstract

The aim of the article is to provide a summary of the work carried out in the framework of a research project funded by the Italian Ministry of Research. The main goal of the activity was to introduce multiple tools for reliable, affordable, and high-performance microwave hyperthermia for cancer therapy. The proposed methodologies and approaches target microwave diagnostics, accurate in vivo electromagnetic parameters estimation, and improvement in treatment planning using a single device. This article provides an overview of the proposed and tested techniques and shows their complementarity and interconnection. To highlight the approach, we also present a novel combination of specific absorption rate optimization via convex programming with a temperature-based refinement method implemented to mitigate the effect of thermal boundary conditions on the final temperature map. To this purpose, numerical tests were carried out for both simple and anatomically detailed 3D scenarios for the head and neck region. These preliminary results show the potential of the combined technique and improvements in the temperature coverage of the tumor target with respect to the case wherein no refinement is adopted.

Indexed as

convex programmingelectromagnetic fieldelectromagnetic propertiesfield intensity shaping and focusinghyperthermia treatment planning

Identifiers

PMID36900351
PMCPMC10000666

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read24
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.