ArticleScientific reports2023
Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 6 citations in OpenAlex.
- Evaluation of a merging-based approach for improving patient-specific quality assurance in proton and carbon-ion radiotherapy: a comparative study with conventional single-isocentre experience.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026Article
- A novel audit methodology to improve detection of planning and delivery errors in passive motion management.Physics and imaging in radiation oncology · 2026Article
- Site-Specific Assessment of Statistical Process Control to Set Tolerance and Action Limits for Patient-Specific Quality Assurance in RapidArc Treatment Delivery.Journal of biomedical physics & engineering · 2025Article
- A comprehensive site-specific analysis of patient-specific quality assurance based on dose volume histogram of RapidArc treatment delivery.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2024Article
- Economic statistical model of the np chart for monitoring defectives.Scientific reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In radiotherapy, air-filled ion chamber detectors are ubiquitously used in routine dose measurements for treatment planning. However, its use has been restricted by intrinsic low spatial resolution barriers. We developed one procedure for patient-specific quality assurance (QA) in arc radiotherapy by coalescing two adjacent measurement images into a single image to improve spatial resolution and sampling frequency, and investigated how different spatial resolutions affect the QA results. PTW 729 and 1500 ion chamber detectors were used for dosimetric verification via coalescing two measurements with 5 mm-couch shift and the isocenter, and only isocenter measurement, which we call coalescence and standard acquisition (SA). Statistical process control (SPC), process capability analysis (PCA), and receiver operating characteristic (ROC) curve were used to compare the performance of the two procedures in determining tolerance levels and identifying clinically relevant errors. By analyzing 1256 γ values calculated on interpolated data points, our results indicated that detector 1500 showed higher averages in coalescence cohorts at different tolerance criteria and the dispersion degrees were spread out smaller. Detector 729 yielded a slightly lower process capability of 0.79, 0.76, 1.10, and 1.34, but detector 1500 exhibited somewhat different results of 0.94, 1.42, 1.19, and 1.60 in magnitude. The results of SPC individual control chart showed that cases in coalescence cohorts with γ values lowering its lower control limit (LCL) were greater than those in SA cohorts for detector 1500. A combination of the width of multi-leaf collimator (MLC) leaf, the cross-sectional area of the single detector, and the spacing between adjacent detectors might lead to discrepancies in percent γ values across diverse spatial resolution scenarios. The accuracy of reconstructed volume dose is mainly determined by the interpolation algorithm used in dosimetric systems. The magnitude of filling factor in the ion chamber detectors determined its ability to detect dose deviations. SPC and PCA results indicated that coalescence procedure could detect more potential failure QA results than SA while enhancing action thresholds.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.