Evidence map›Paper›PMID 36898753›Full record

ArticleBMJ open2023

Ultrasound-guided Jamshidi needle puncture to reduce radiation exposure during percutaneous pedicle screw placement: study protocol for a randomised controlled trial.

Tong Wu, Yi-Feng Chen, Ying Huang, Fan-He Meng, Jing-Han Lu, Da Liu

Abstract readClinical Trial Protocol
In one paragraph

Article in BMJ open, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tong WuDepartment of Orthopedics, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China.ORCID 0000-0001-8810-4135
Yi-Feng ChenDepartment of Orthopedics, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China.
Ying HuangDepartment of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China.
Fan-He MengDepartment of Orthopedics, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China.
Jing-Han LuDepartment of Orthopedics, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China.
Da LiuDepartment of Orthopedics, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China spinecmu@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPercutaneous pedicle screw placement (PPSP) is a minimally invasive procedure highly dependent on fluoroscopic guidance, which results in increased radiation exposure and prolonged operative time. Ultrasound can image the lumbar paravertebral anatomy and the needle trajectory in real time, which may help reduce the use of fluoroscopy and radiation dose in PPSP. We will conduct a parallel randomised controlled trial to mainly investigate the effect of ultrasound guidance in radiation reduction during PPSP. METHODS AND ANALYSIS: A total of 42 patients will be recruited and randomly assigned to the intervention group and the control group at a 1:1 ratio. In the intervention group, we will use ultrasound in combination with fluoroscopy to guide the insertion of the Jamshidi needles. In the control group, PPSP will be performed under conventional fluoroscopic guidance. The primary outcomes are the cumulative fluoroscopy time (s), radiation dose (mGy) and exposure times of screw placement. The secondary outcomes are insertion time of guidewire, rate of pedicle perforation, rate of facet joint violation, visual analogue scale for back pain, Oswestry Disability Index and complications. The participants, outcome assessors and data analysts will be blinded to allocation. ETHICS AND DISSEMINATION: The trial was approved by the research ethics committee of Shengjing Hospital, China Medical University. The results will be presented at academic seminars and submitted for publication in peer-reviewed journals.This study involves human participants and was approved by Research Ethics Committee of Shengjing Hospital, China Medical University reference number:2022PS704K. Participants gave informed consent to participate in the study before taking part. TRIAL REGISTRATION NUMBER: ChiCTR2200057131.

Indexed as

Pedicle ScrewsRadiation ExposureSpinal FusionSurgery, Computer-AssistedHumansLumbar VertebraeNeedlesPuncturesRandomized Controlled Trials as TopicUltrasonography, InterventionalOrthopaedic & trauma surgerySpineUltrasound

Identifiers

PMID36898753
PMCPMC10008456

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.