Evidence map›Paper›PMID 36897475›Full record

ArticleThe Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology2023

Management of PDA device closure complicated by severe hemolysis by transcatheter retrieval and deployment of new device.

Aamir Rashid, Ajaz Lone, Hilal Rather, Imran Hafeez

Open access · diamondFull text read
In one paragraph

Article in The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Aamir RashidDepartment of Cardiology, SKIMS, Soura, Srinagar, J& K, India. aamirrashid11@yahoo.co.in.
Ajaz LoneDepartment of Cardiology, SKIMS, Soura, Srinagar, J& K, India.
Hilal RatherDepartment of Cardiology, SKIMS, Soura, Srinagar, J& K, India.
Imran HafeezDepartment of Cardiology, SKIMS, Soura, Srinagar, J& K, India.
Sher-i-Kashmir Institute of Medical Sciences · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHemolysis after Patent ductus arteriosus (PDA) device closure is rare. Although in most cases, hemolysis settles on its own; however, in some cases it may not settle spontaneously and may require additional procedures like putting additional coils, gel foam or thrombin instillation, balloon occlusion, or removing it surgically. We report a case of adult PDA device closure who persisted with hemolysis and was managed by transcatheter retrieval. CASE PRESENTATION: A 52-year-old gentleman presented to us with a diagnosis of large PDA with operable hemodynamics. Descending thoracic aortic Angio showed a large 11 mm PDA. Transcatheter device closure was done in the same sitting with a 16 × 14 Amplatzer Ductal Occluder I(ADO) device,;however, after device release, the aortic end of the device was not fully formed and there was residual flow. The next morning patient started with gross hematuria with persistent residual flow. We tried to manage with conservative means including hydration, and blood transfusion; however, residual flow persisted for 10 days and his hemoglobin dropped from 13 gm/dl preprocedural to 7 gm/dl, creatinine increased from 0.5 mg/dl to 1.9 mg/dl, bilirubin increased to 3.5 mg/dl & urine showed hemoglobinuria. As the patient continued to deteriorate it was planned to retrieve the device by transcatheter approach. 10 French amplatzer sheath was parked in the pulmonary artery near the ductus. We tried with a combination of multiple catheters and Gooseneck snare (10 mm) and finally, we successfully retrieved with a combination of Multipurpose (MP) catheter and 10 mm Gooseneck snare. After that, we closed the defect successfully with a double disk device (muscular Ventricular septal defect 14 mm Amplatzer). The patient's hematuria settled and was discharged after 2 days with normal hemoglobin and creatinine.

conclusionsPatent ductus arteriosus ADO 1 device should not be released if the aortic end of the disk is not fully formed Patient should be carefully monitored for hemolysis if evidence of residual shunt and given supportive treatment. If conservative treatment fails, residual flow needs to be eliminated. Transcatheter retrieval although technically challenging is a feasible treatment. A muscular VSD device is a good alternative to the usual PDA device to close PDA, especially in adults.

Indexed as

Amplatzer duct occluderCatheter interventionHemolysis

Identifiers

PMID36897475
PMCPMC10006361
OpenAlexW4323808527

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read8
Read underepoch 390

Registered trials

None linked