Does fluoroscopy improve baseplate position compared to conventional technique in reverse shoulder arthroplasty? A preliminary study.

María Galán-Olleros, Yaiza Lopiz, Gabriel Ciller, Borja Alcobía-Díaz, Carlos García-Fernández, Fernando Marco

Open access · bronzeAbstract read
In one paragraph

Article in Shoulder & elbow, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 90% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

María Galán-OllerosShoulder and Elbow Unit, Orthopaedic Surgery and Traumatology Department, Clínico San Carlos Hospital, Madrid, Spain.ORCID https://orcid.org/0000-0001-9074-9215
Yaiza LopizShoulder and Elbow Unit, Orthopaedic Surgery and Traumatology Department, Clínico San Carlos Hospital, Madrid, Spain.
Gabriel CillerShoulder and Elbow Unit, Orthopaedic Surgery and Traumatology Department, Clínico San Carlos Hospital, Madrid, Spain.
Borja Alcobía-DíazShoulder and Elbow Unit, Orthopaedic Surgery and Traumatology Department, Clínico San Carlos Hospital, Madrid, Spain.
Carlos García-FernándezShoulder and Elbow Unit, Orthopaedic Surgery and Traumatology Department, Clínico San Carlos Hospital, Madrid, Spain.
Fernando MarcoShoulder and Elbow Unit, Orthopaedic Surgery and Traumatology Department, Clínico San Carlos Hospital, Madrid, Spain.
Hospital Clínico San Carlos · ESUniversidad Complutense de Madrid · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Accurate placement of glenoid component in reverse shoulder arthroplasty remains a challenge for surgeons of all levels of expertise; however, no studies have evaluated the utility of fluoroscopy as a surgical assistance method. Methods: Prospective comparative study of 33 patients undergoing primary reverse shoulder arthroplasty during a 12-month period. Fifteen patients had a baseplate placed using the conventional "free hand" technique (control group), and 18 patients using intraoperative fluoroscopy assistance group, in a case-control design. Postoperative glenoid position was evaluated on postoperative Computed Tomography (CT) scan. Results: The mean deviation of version and inclination for fluoroscopy assistance vs. control group was 1.75° (0.675-3.125) vs. 4.2° (1.975-10.45) (p = .015), and 3.85° (0-7.225) vs. 10.35° (4.35-18.75) (p = .009). The distance from the central peg midpoint to the inferior glenoid rim (fluoroscopy assistance 14.61 mm/control 4.75 mm, p = .581) and the surgical time (fluoroscopy assistance 1.93 ± 0.57/control 2.18 ± 0.44 h, p = .400) showed no differences, with an average radiation dose of 0.45 mGy and fluoroscopy time of 14 s. Conclusions: Accurate axial and coronal scapular plane positioning of glenoid component is improved with intraoperative fluoroscopy at the cost of a greater radiation dose and without differences in surgical time. Comparative studies are needed to determine whether their use in relation to more expensive surgical assistance systems result in similar effectiveness.

Indexed as

fluoroscopyglenoid componentorthopaedic proceduresreverse shoulder arthroplastyShoulder replacement arthroplasty

Identifiers

PMID36895612
PMCPMC9990097
OpenAlexW3167282847

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.