The influence of body weight index on initial stability of uncemented femoral knee protheses: A finite element study.

Qian Wan, Aobo Zhang, Yang Liu, Hao Chen, Jiangbo Zhang, Haowen Xue, Qing Han, Jincheng Wang

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
3.5field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Qian WanDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China.
Aobo ZhangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China.
Yang LiuDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China.
Hao ChenDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China.
Jiangbo ZhangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China.
Haowen XueDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China.
Qing HanDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China.
Jincheng WangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China.
Second Affiliated Hospital of Jilin University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and objective: Obesity is one of the risk factors for osteoarthritis. The end-stage treatment for osteoarthritis is total knee arthroplasty (TKA). However, it remains controversial whether a high body mass index (BMI) affects the initial stability of the femoral prosthesis after TKA. Finite element analysis (FEA) was used to investigate this question in this study. Methods: Four femur models that assembled with TKA femoral components were reconstructed and divided into high BMI group and normal BMI group. The three-dimensional femurs were modeled and assigned inhomogeneous materials based on computed tomography (CT) images. Then each FEA model was applied with gait and deep bend loading conditions to evaluate the maximum principal strain on the distal femur and the relative micromotion between the femur and prosthesis. Results: The mean strain of the high BMI group increased by 32.7% (936.9 με versus 706.1 με) and 50.9% (2064.5 με versus 1368.2 με) under gait and deep bend loading conditions, respectively, compared to the normal BMI group. Meanwhile, the mean micromotion of the high BMI group increased by 41.6% (2.77 μm versus 1.96 μm) and 58.5% (62.1 μm versus 39.2 μm), respectively. Under gait condition, the maximum micromotion for high BMI group was 33.8 μm and would compromise the initial stability. Under deep bend condition, the maximum strain and micromotion exceeded -7300 με and 28 μm for both groups. Conclusion: High BMI caused higher strain on the bone and higher micromotion between the prosthesis and the femur. Gait activities could be risky for prosthesis stability in high BMI group while be safe in normal group. Deep bend activities were highly dangerous for both groups with high BMI and normal BMI and should be avoided.

Indexed as

Aseptic looseningBody weight indexFemoral componentFinite element analysisInitial stabilityTotal knee arthroplasty

Identifiers

PMID36895366
PMCPMC9988490
OpenAlexW4321201515

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.