"Will I change nodule management recommendations if I change my CAD system?"-impact of volumetric deviation between different CAD systems on lesion management.

Alan A Peters, Andreas Christe, Oyunbileg von Stackelberg, Moritz Pohl, Hans-Ulrich Kauczor, Claus Peter Heußel, Mark O Wielpütz, Lukas Ebner

Open access · hybridAbstract read
In one paragraph

Article in European radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Alan A PetersDepartment of Diagnostic and Interventional Radiology, University Hospital of Heidelberg, Im Neuenheimer Feld 672, Heidelberg, Germany. alan.peters@insel.ch.
Andreas ChristeDepartment of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, 3010, Freiburgstrasse, Switzerland.
Oyunbileg von StackelbergDepartment of Diagnostic and Interventional Radiology, University Hospital of Heidelberg, Im Neuenheimer Feld 672, Heidelberg, Germany.
Moritz PohlInstitute of Medical Biometry, University of Heidelberg, Im Neuenheimer Feld 130.3, 69120, Heidelberg, Germany.
Hans-Ulrich KauczorDepartment of Diagnostic and Interventional Radiology, University Hospital of Heidelberg, Im Neuenheimer Feld 672, Heidelberg, Germany.
Claus Peter HeußelDepartment of Diagnostic and Interventional Radiology, University Hospital of Heidelberg, Im Neuenheimer Feld 672, Heidelberg, Germany.
Mark O WielpützDepartment of Diagnostic and Interventional Radiology, University Hospital of Heidelberg, Im Neuenheimer Feld 672, Heidelberg, Germany.
Lukas EbnerDepartment of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, 3010, Freiburgstrasse, Switzerland.
Heidelberg University · DEUniversity of Bern · CHGerman Center for Lung Research · DEUniversity Hospital Heidelberg · DEZimmer Biomet (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate and compare the measurement accuracy of two different computer-aided diagnosis (CAD) systems regarding artificial pulmonary nodules and assess the clinical impact of volumetric inaccuracies in a phantom study.

methodsIn this phantom study, 59 different phantom arrangements with 326 artificial nodules (178 solid, 148 ground-glass) were scanned at 80 kV, 100 kV, and 120 kV. Four different nodule diameters were used: 5 mm, 8 mm, 10 mm, and 12 mm. Scans were analyzed by a deep-learning (DL)-based CAD and a standard CAD system. Relative volumetric errors (RVE) of each system vs. ground truth and the relative volume difference (RVD) DL-based vs. standard CAD were calculated. The Bland-Altman method was used to define the limits of agreement (LOA). The hypothetical impact on LungRADS classification was assessed for both systems.

resultsThere was no difference between the three voltage groups regarding nodule volumetry. Regarding the solid nodules, the RVE of the 5-mm-, 8-mm-, 10-mm-, and 12-mm-size groups for the DL CAD/standard CAD were 12.2/2.8%, 1.3/ - 2.8%, - 3.6/1.5%, and - 12.2/ - 0.3%, respectively. The corresponding values for the ground-glass nodules (GGN) were 25.6%/81.0%, 9.0%/28.0%, 7.6/20.6%, and 6.8/21.2%. The mean RVD for solid nodules/GGN was 1.3/ - 15.2%. Regarding the LungRADS classification, 88.5% and 79.8% of all solid nodules were correctly assigned by the DL CAD and the standard CAD, respectively. 14.9% of the nodules were assigned differently between the systems.

conclusionsPatient management may be affected by the volumetric inaccuracy of the CAD systems and hence demands supervision and/or manual correction by a radiologist. KEY POINTS: • The DL-based CAD system was more accurate in the volumetry of GGN and less accurate regarding solid nodules than the standard CAD system. • Nodule size and attenuation have an effect on the measurement accuracy of both systems; tube voltage has no effect on measurement accuracy. • Measurement inaccuracies of CAD systems can have an impact on patient management, which demands supervision by radiologists.

Indexed as

Lung NeoplasmsMultiple Pulmonary NodulesSolitary Pulmonary NoduleDiagnosis, Computer-AssistedHumansPhantoms, ImagingRadiographic Image Interpretation, Computer-AssistedRadiologistsSensitivity and SpecificityTomography, X-Ray ComputedArtificial intelligenceComputer-assisted diagnosisDeep learningImaging phantomsLung neoplasms

Identifiers

PMID36894752
PMCPMC10326095
OpenAlexW4323657808

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.