ArticleEuropean radiology2023
"Will I change nodule management recommendations if I change my CAD system?"-impact of volumetric deviation between different CAD systems on lesion management.
Article in European radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 9 citations in OpenAlex.
- Lung nodule detection and potential impact on guideline-based management: a retrospective post-market evaluation of three commercial software systems.European radiology · 2026Article
- Impact of reader experience on the time-saving potential of a novel computer-aided tool for Ann Arbor staging of pediatric hodgkin lymphoma.Frontiers in nuclear medicine · 2026Article
- Performance Evaluation of Four Deep Learning-Based CAD Systems and Manual Reading for Pulmonary Nodules Detection, Volume Measurement, and Lung-RADS Classification Under Varying Radiation Doses and Reconstruction Methods.Diagnostics (Basel, Switzerland) · 2025Article
- Comparison of AI software tools for automated detection, quantification and categorization of pulmonary nodules in the HANSE LCS trial.Scientific reports · 2024Article
- Impact of artificial intelligence assistance on pulmonary nodule detection and localization in chest CT: a comparative study among radiologists of varying experience levels.Scientific reports · 2024Article
- Impact of Simulated Reduced-Dose Chest CT on Diagnosing Pulmonary T1 Tumors and Patient Management.Diagnostics (Basel, Switzerland) · 2024Article
- Prospective evaluation of deep learning image reconstruction for Lung-RADS and automatic nodule volumetry on ultralow-dose chest CT.PloS one · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo evaluate and compare the measurement accuracy of two different computer-aided diagnosis (CAD) systems regarding artificial pulmonary nodules and assess the clinical impact of volumetric inaccuracies in a phantom study.
methodsIn this phantom study, 59 different phantom arrangements with 326 artificial nodules (178 solid, 148 ground-glass) were scanned at 80 kV, 100 kV, and 120 kV. Four different nodule diameters were used: 5 mm, 8 mm, 10 mm, and 12 mm. Scans were analyzed by a deep-learning (DL)-based CAD and a standard CAD system. Relative volumetric errors (RVE) of each system vs. ground truth and the relative volume difference (RVD) DL-based vs. standard CAD were calculated. The Bland-Altman method was used to define the limits of agreement (LOA). The hypothetical impact on LungRADS classification was assessed for both systems.
resultsThere was no difference between the three voltage groups regarding nodule volumetry. Regarding the solid nodules, the RVE of the 5-mm-, 8-mm-, 10-mm-, and 12-mm-size groups for the DL CAD/standard CAD were 12.2/2.8%, 1.3/ - 2.8%, - 3.6/1.5%, and - 12.2/ - 0.3%, respectively. The corresponding values for the ground-glass nodules (GGN) were 25.6%/81.0%, 9.0%/28.0%, 7.6/20.6%, and 6.8/21.2%. The mean RVD for solid nodules/GGN was 1.3/ - 15.2%. Regarding the LungRADS classification, 88.5% and 79.8% of all solid nodules were correctly assigned by the DL CAD and the standard CAD, respectively. 14.9% of the nodules were assigned differently between the systems.
conclusionsPatient management may be affected by the volumetric inaccuracy of the CAD systems and hence demands supervision and/or manual correction by a radiologist. KEY POINTS: • The DL-based CAD system was more accurate in the volumetry of GGN and less accurate regarding solid nodules than the standard CAD system. • Nodule size and attenuation have an effect on the measurement accuracy of both systems; tube voltage has no effect on measurement accuracy. • Measurement inaccuracies of CAD systems can have an impact on patient management, which demands supervision by radiologists.