Evidence map›Paper›PMID 36892640›Full record

ArticleEuropean radiology2023

Virtual monochromatic images of dual-energy CT as an alternative to single-energy CT: performance comparison using a detectability index for different acquisition techniques.

Hiroki Kawashima, Katsuhiro Ichikawa, Hiroshi Ueta, Tadanori Takata, Wataru Mitsui, Hiroji Nagata

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hiroki KawashimaFaculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942, Japan. kawa3@med.kanazawa-u.ac.jp.ORCID http://orcid.org/0000-0003-1223-8756
Katsuhiro IchikawaFaculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942, Japan.
Hiroshi UetaRadiology Division, Kanazawa University Hospital, 13-1 Takara-Machi, Kanazawa, 920-8641, Japan.
Tadanori TakataRadiology Division, Kanazawa University Hospital, 13-1 Takara-Machi, Kanazawa, 920-8641, Japan.
Wataru MitsuiRadiology Division, Kanazawa University Hospital, 13-1 Takara-Machi, Kanazawa, 920-8641, Japan.
Hiroji NagataSection of Radiological Technology, Department of Medical Technology, Kanazawa Medical University Hospital, Daigaku 1-1, Uchinada, Kahoku, 920-0293, Japan.

Funding

Japan Society for the Promotion of Science JSPS KAKENHI Grant Number JP20K16694
6 · The paper itself

Abstract

objectivesTo investigate the performance of virtual monochromatic (VM) images with the same dose and iodine contrast as those for single-energy (SE) images using five dual-energy (DE) scanners with DE techniques: two generations of fast kV switching (FKS), two generations of dual source (DS), and one split filter (SF).

methodsA water-bath phantom with a diameter of 300 mm, which contains one rod-shaped phantom made of a material equivalent to soft-tissue and two rod-shaped phantoms made of diluted iodine (2 and 12 mg/mL), was scanned using both SE (120, 100, and 80 kV) and DE techniques with the same CT dose index in each scanner. The VM energy at which the CT number of the iodine rod is closest to that of each SE tube voltage was determined as the equivalent energy (Eeq). A detectability index (d') was calculated from the noise power spectrum, the task transfer functions, and a task function corresponding to each rod. The percentage of the d' value of the VM image to that of the corresponding SE image was calculated for performance comparison.

resultsThe average percentages of d' of FKS1, FKS2, DS1, DS2, and SF were 84.6%, 96.2%, 94.3%, 107%, and 104% for 120 kV-Eeq; 75.9%, 91.2%, 88.2%, 99.2%, and 82.6% for 100 kV-Eeq; 71.6%, 88.9%, 82.6%, 85.2%, and 62.3% for 80 kV-Eeq, respectively.

conclusionThe performance of VM images was on the whole inferior to that of SE images especially at low equivalent energy levels, depending on the DE techniques and their generations. KEY POINTS: • This study evaluated the performance of VM images with the same dose and iodine contrast as those for SE images using five DE scanners. • The performance of VM images varied with the DE techniques and their generations and was mostly inferior at low equivalent energy levels. • The results highlight the importance of distribution of available dose over the two energy levels and spectral separation for the performance improvement of VM images.

Indexed as

IodineTomography, X-Ray ComputedContrast MediaHumansPhantoms, ImagingRadiation DosageContrast MediaIodineComparative studyIodineRadiation dosageTomography, X-ray computed

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.