Evidence map›Paper›PMID 36891853›Full record

ArticleJournal of synchrotron radiation2023

High-energy X-ray micro-laminography to visualize microstructures in dense planar objects.

Masato Hoshino, Kentaro Uesugi, Takuya Imai

Open access · goldFull text read
In one paragraph

Article in Journal of synchrotron radiation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Masato HoshinoJapan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198, Japan.ORCID 0000-0002-4167-2706
Kentaro UesugiJapan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198, Japan.ORCID 0000-0003-2579-513X
Takuya ImaiFukui Prefectural University, 4-1-1 Matsuoka-kenjojima, Eiheiji, Fukui 910-1195, Japan.
Japan Synchrotron Radiation Research Institute · JPFukui Prefectural University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High-energy X-ray micro-laminography has been developed to observe inner- and near-surface structures in dense planar objects that are not suitable for observation by X-ray micro-tomography. A multilayer-monochromator-based high-intensity X-ray beam with energy of 110 keV was used for high-energy and high-resolution laminographic observations. As a demonstration of high-energy X-ray micro-laminography for observing dense planar objects, a compressed fossil cockroach on a planar matrix surface was analyzed with effective pixel sizes of 12.4 µm and 4.22 µm for wide field of view and high-resolution observations, respectively. In this analysis, the near-surface structure was clearly observed without undesired X-ray refraction-based artifacts from outside of the region of interest, a problem typical in tomographic observations. Another demonstration visualized fossil inclusions in a planar matrix. Micro-scale features of a gastropod shell and micro-fossil inclusions in the surrounding matrix were clearly visualized. When observing local structures in the dense planar object with X-ray micro-laminography, the penetrating path length in the surrounding matrix can be shortened. This is a significant advantage of X-ray micro-laminography where desired signals generated at the region of interest including optimal X-ray refraction effectively contribute to image formation without being disturbed by undesired interactions in the thick and dense surrounding matrix. Therefore, X-ray micro-laminography allows recognition of the local fine structures and slight difference in the image contrast of planar objects undetectable in a tomographic observation.

Indexed as

fossilshigh-energy X-raymicro-laminographyX-ray refraction contrast

Identifiers

PMID36891853
PMCPMC10000797
OpenAlexW4319073325

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read3
identifiers read2
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.