Evidence map›Paper›PMID 36891523›Full record

ArticleResearch and practice in thrombosis and haemostasis2023

Interference in point-of-care international normalized ratio monitoring in patients with lupus anticoagulant is correlated with anti-β2-glycoprotein I antibody titers.

Tessa Noordermeer, Rolf T Urbanus, Chong Y Wong, Janna J Jansma, Nynke M Wiersma, Minka Zivkovic, Albert Huisman, Maarten Limper

Open access · goldAbstract read
In one paragraph

Article in Research and practice in thrombosis and haemostasis, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.

  1. Evaluating the Efficacy and Safety of Direct Oral Anticoagulants Compared to Vitamin K Antagonists in Patients with Antiphospholipid Syndrome: Updated Systematic Review and Meta-Analysis.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis
    Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Tessa NoordermeerCenter for Benign Hematology, Thrombosis and Haemostasis, Van Creveldkliniek, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
Rolf T UrbanusCenter for Benign Hematology, Thrombosis and Haemostasis, Van Creveldkliniek, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
Chong Y WongDepartment of Rheumatology and Clinical Immunology, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
Janna J JansmaCentral Diagnostic Laboratory, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
Nynke M WiersmaDepartment of Thrombosis and Anticoagulation, Diagnostic Center Saltro, Utrecht, the Netherlands.
Minka ZivkovicCenter for Benign Hematology, Thrombosis and Haemostasis, Van Creveldkliniek, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
Albert HuismanCentral Diagnostic Laboratory, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
Maarten LimperDepartment of Rheumatology and Clinical Immunology, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
Utrecht University · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Patients with antiphospholipid syndrome (APS) receive anticoagulant therapy with vitamin K antagonists (VKAs) to prevent recurrent thrombosis. VKA treatment requires strict monitoring with an international normalized ratio (INR). It is known that lupus anticoagulants (LAs) can lead to elevated INR results with point-of-care-testing (POCT) devices, which could result in inadequate adaptation of anticoagulant therapy. Objective: To determine discrepancies between POCT-INR and laboratory-INR in patients who are LA-positive on VKA therapy. Methods: Paired INR testing was performed with 1 POCT device (CoaguChek XS) and 2 laboratory assays (Owren and Quick method) in 33 patients with LA-positive APS on VKA in a single-center cross-sectional study. Patients were tested for anti-β2-glycoprotein I, anticardiolipin, and antiphosphatidylserine/prothrombin immunoglobulin (Ig) G and IgM antibodies. Agreement between assays was evaluated with Spearman's correlation, Lin's correlation coefficient, and Bland-Altman plots. Agreement limits were considered satisfactory if differences were ≤20% as determined by the Clinical and Laboratory Standards Institute. Results: We found poor agreement between POCT-INR and laboratory-INR based on Lin's concordance correlation coefficient (ρ Conclusion: There is a disagreement between INR values measured with the CoaguChek XS and laboratory-INR in a proportion of patients with LA. Consequently, laboratory-INR monitoring should be preferred over POCT-INR monitoring in patients with LA-positive APS, especially in patients with high anti-β2-glycoprotein IgG antibody titers.

Indexed as

anticoagulantsinternational normalized ratiolupus coagulation inhibitorpoint-of-care testingwarfarin

Identifiers

PMID36891523
PMCPMC9986099
OpenAlexW4313890497

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.