Evidence map›Paper›PMID 36891506›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2023

Effect of Violet Light-Filtering and Manufacturing Improvements in an Extended Depth-of-Focus Intraocular Lens on Visual Performance.

Marrie van der Mooren, Aixa Alarcon, Mark D Jenkins Sanchez, Daniel H Chang

Registry-linked trialAbstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06567834 (Clinical Evaluation of Violet Light Filtration and High-resolution Lathing on a Diffractive Extended Depth of Focus Intraocular Lens), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06567834 nacompletednot on this map

Clinical Evaluation of Violet Light Filtration and High-resolution Lathing on a Diffractive Extended Depth of Focus Intraocular Lens (IOL)

TypeinterventionalSponsorEmpire Eye and Laser CenterRan2022 to 2023Enrolled60ConditionsCataract, PresbyopiaArmsTecnis Symfony Optiblue/Tecnis Symfony Optiblue Toric (Models ZXR00V/ZXW150), Tecnis Symfony/Tecnis Symfony Toric (Models ZXR00/ZXT150)
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Marrie van der MoorenJohnson & Johnson Surgical Vision, Inc., Groningen, Netherlands.
Aixa AlarconJohnson & Johnson Surgical Vision, Inc., Groningen, Netherlands.
Mark D Jenkins SanchezJohnson & Johnson Surgical Vision, Inc., Groningen, Netherlands.
Daniel H ChangEmpire Eye and Laser Center, Bakersfield, CA, USA.ORCID 0000-0001-6307-6342

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To assess the experimental visual performance and dysphotopsia characteristics of the new Tecnis Symfony OptiBlue extended-depth-of-focus with violet light-filtering (ZXR00V) intraocular lens (IOL) compared with the colorless Tecnis Symfony (ZXR00) IOL. Methods: Range of vision was assessed with simulated visual acuity defocus curves, predicted by white light through focus modulation transfer function (MTF) measurements. The clinical visual acuity defocus curve of the ZXR00 IOL was used to validate the predicted range of vision. Image quality was compared by measuring white light MTF at a spatial frequency of 15 cycles per degree (c/deg) for 3 mm and 5 mm pupil diameters with optical powers of 5 D, 20 D, and 34 D using the average corneal eye (ACE) model with the average spherical and chromatic aberration of the cataract population. Effects on dysphotopsias were predicted by measurement and computer simulation of light scatter (straylight parameter) and subsequent determination of retinal veiling luminance (RVL) in vitro. Contrast enhancement under challenging light conditions was calculated based on the effects in RVL. Results: The simulated visual acuity defocus curves and image quality outcomes were comparable between the ZXR00V and ZXR00 IOLs. The area under the straylight curve for the straylight parameter showed a 19% improvement in halo performance with ZXR00V versus ZXR00. A 12% to 17% reduction in RVL was achieved in favor of ZXR00V over ZXR00, which enhanced contrast vision by 9% to 13% under challenging light conditions. Conclusion: The violet light-filtering technology and improved manufacturing of ZXR00V delivers a comparable range of vision and tolerance to refractive error to ZXR00 while mitigating dysphotopsias and enhancing contrast vision.

Indexed as

dysphotopsia profilepresbyopia-correcting IOLretinal veiling luminancestraylight parameterviolet light-filtering IOL

Identifiers

PMID36891506
PMCPMC9986957

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.