Evidence map›Paper›PMID 36891018›Full record

ArticleCureus2023

Entrance Skin Dose (ESD) and Bucky Table Induced Backscattered Dose (BTI-BSD) in Abdominal Radiography With nanoDot Optically Stimulated Luminescence Dosimeter (OSLD).

Inayatullah Shah Sayed, Nurul Shuhada Roslan, Waliullah Shah Syed

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Radiation Overuse in Intensive Care Units.Tomography (Ann Arbor, Mich.) · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 2 countries.

Inayatullah Shah SayedDepartment of Diagnostic Imaging and Radiotherapy, International Islamic University Malaysia, Kuantan Campus, Kuantan, MYS.
Nurul Shuhada RoslanDepartment of Diagnostic Imaging and Radiotherapy, International Islamic University Malaysia, Kuantan Campus, Kuantan, MYS.
Waliullah Shah SyedDepartment of Applied Sciences, Stanford International College, Mississauga, CAN.
International Islamic University Malaysia · MY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In radiography, inconsistencies in patients' measured entrance skin dose (ESD) exist. There is no published research on the bucky table induced backscattered radiation dose (BTI-BSD). Thus, we aimed to ascertain ESD, calculate the BTI-BSD in abdominal radiography with a nanoDot OSLD, and compare the ESD results with the published data. A Kyoto Kagaku PBU-50 phantom (Kyoto, Japan) in an antero-posterior supine position was exposed, selecting a protocol used for abdominal radiography. The central ray of x-ray beam was pointed at the surface of abdomen at the navel, where a nanoDot dosimeter was placed to measure ESD. For the BTI-BSD, exit dose (ED) was determined by placing a second dosimeter on the exact opposite side (backside) of the phantom from the dosimeter used to determine (ESD) with and without bucky table at identical exposure parameters. The BTI-BSD was calculated as the difference between ED with and without bucky table. The ESD, ED, and BTI-BSD were measured in milligray (mGy). ESD mean values with and without bucky table were 1.97 mGy and 1.84 mGy, whereas ED values were 0.062 mGy and 0.052 mGy, respectively. Results show 2-26% lower ESD values with nanoDot OSLD. The BTI-BSD mean value was found to be approximately 0.01 mGy. A local dose reference level (LDRL) can be established using ESD data to safeguard patients from unnecessary radiation. In addition, to minimize the risk of BTI-BSD in patients in radiography, the search for the use or fabrication of a new, lower atomic number material for the bucky table is suggested.

Indexed as

backscattered radiation dosebucky tabledosimetryesdexposurenanodot osldradiation protectionradiography

Identifiers

PMID36891018
PMCPMC9986971
OpenAlexW4319080671

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.