Evidence map›Paper›PMID 36883097›Full record

ArticleCureus2023

Augmented Reality Navigation Can Achieve Accurate Coronal Component Alignment During Total Knee Arthroplasty.

Kyle M Bennett, Andrew Griffith, Francesca Sasanelli, Isaac Park, Simon Talbot

Abstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Augmented Reality-Guided Individualized Total Knee Arthroplasty: Initial Clinical Implementation and Results.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2026
    Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kyle M BennettDepartment of Orthopaedic Surgery, Western Health, Melbourne, AUS.
Andrew GriffithDepartment of Orthopaedic Surgery, Western Health, Melbourne, AUS.
Francesca SasanelliDepartment of Orthopaedic Surgery, Western Health, Melbourne, AUS.
Isaac ParkDepartment of Orthopaedic Surgery, Melbourne Health, Melbourne, AUS.
Simon TalbotDepartment of Orthopaedic Surgery, Western Health, Melbourne, AUS.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Computer-navigated knee arthroplasty has been shown to improve accuracy over conventional instruments. The next generation of computer assistance is being developed using augmented reality. The accuracy of augmented reality navigation has not been established. Methods From April 2021 to October 2021, a prospective, consecutive series of 20 patients underwent total knee arthroplasty utilising an augmented reality-assisted navigation system (ARAN). The coronal and sagittal alignment of the femoral and tibial bone cuts was measured using the ARAN and the final position of the components was measured on postoperative CT scans. The absolute difference between the measurements was recorded to determine the accuracy of the ARAN. Results Two cases were excluded due to segmentation errors, leaving 18 cases for analysis. The ARAN produced a mean absolute error of 1.4°, 2.0°, 1.1° and 1.6° for the femoral coronal, femoral sagittal, tibial coronal and tibial sagittal alignments, respectively. No outliers (absolute error of >3°) were identified in femoral coronal or tibial coronal alignment measurements. Three outliers were identified in tibial sagittal alignment, with all cases demonstrating less tibial slope (by 3.1°, 3.3° and 4°). Five outliers were identified in femoral sagittal alignment and in all cases, the component was more extended (3.1°, 3.2°, 3.2°, 3.4° and 3.9°). The mean operative time significantly decreased from the first nine augmented reality cases to the final nine cases by 11 minutes (p<0.05). There was no difference in the accuracy between the early and late ARAN cases. Conclusion Augmented reality navigation can achieve accurate alignment of total knee arthroplasty with a low rate of component malposition in the coronal plane. Acceptable and consistent accuracy can be achieved from the initial adoption of this technique, however, some sagittal outliers were identified and there is a clear learning curve with respect to operating time. The level of evidence was IV.

Indexed as

accuracyaugmented realitycomputer assisted systemorthopaedicstotal knee arthroplasty

Identifiers

PMID36883097
PMCPMC9985958

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.