Evidence map›Paper›PMID 36882505›Full record

ArticleScientific reports2023

Challenges in, and recommendations for, hyperspectral imaging in ex vivo malignant glioma biopsy measurements.

Anna Walke, David Black, Pablo A Valdes, Walter Stummer, Simone König, Eric Suero-Molina

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 2 pooled it
4.8field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 2 syntheses or guidelines pooled it, 21 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. A Wearable Fluorescence Imaging Device for Intraoperative Identification of Human Brain Tumors.IEEE journal of translational engineering in health and medicine · 2024
    Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 3 countries.

Anna WalkeDepartment of Neurosurgery, University Hospital of Münster, Albert-Schweitzer-Campus 1, A1, 48149, Münster, Germany.
David BlackDepartment of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada.
Pablo A ValdesDepartment of Neurosurgery, University of Texas Medical Branch, Galveston, TX, USA.
Walter StummerDepartment of Neurosurgery, University Hospital of Münster, Albert-Schweitzer-Campus 1, A1, 48149, Münster, Germany.
Simone KönigCore Unit Proteomics, Interdisciplinary Centre for Clinical Research, University of Münster, Münster, Germany.
Eric Suero-MolinaDepartment of Neurosurgery, University Hospital of Münster, Albert-Schweitzer-Campus 1, A1, 48149, Münster, Germany. eric.suero@ukmuenster.de.
University Hospital Münster · DEUniversity of Münster · DEThe University of Texas Medical Branch at Galveston · USUniversity of British Columbia · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The visualization of protoporphyrin IX (PPIX) fluorescence with the help of surgical microscopes during 5-aminolevulinic acid-mediated fluorescence-guided resection (FGR) of gliomas is still limited at the tumor margins. Hyperspectral imaging (HI) detects PPIX more sensitively but is not yet ready for intraoperative use. We illustrate the current status with three experiments and summarize our own experience using HI: (1) assessment of HI analysis algorithm using pig brain tissue, (2) a partially retrospective evaluation of our experience from HI projects, and (3) device comparison of surgical microscopy and HI. In (1), we address the problem that current algorithms for evaluating HI data are based on calibration with liquid phantoms, which have limitations. Their pH is low compared to glioma tissue; they provide only one PPIX photo state and only PPIX as fluorophore. Testing the HI algorithm with brain homogenates, we found proper correction for optical properties but not pH. Considerably more PPIX was measured at pH 9 than at pH 5. In (2), we indicate pitfalls and guide HI application. In (3), we found HI superior to the microscope for biopsy diagnosis (AUC = 0.845 ± 0.024 (cut-off 0.75 µg PPIX/ml) vs. 0.710 ± 0.035). HI thus offers potential for improved FGR.

Indexed as

GliomaHyperspectral ImagingAlgorithmsAnimalsBiopsyRetrospective StudiesSwine

Identifiers

PMID36882505
PMCPMC9992662
OpenAlexW4323533588

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.