Evidence map›Paper›PMID 36881780›Full record

ArticleEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2023

Combination of an implantable defibrillator multi-sensor heart failure index and an apnea index for the prediction of atrial high-rate events.

Matteo Bertini, Francesco Vitali, Antonio D'Onofrio, Gennaro Vitulano, Leonardo Calò, Gianluca Savarese, Vincenzo Ezio Santobuono, Antonio Dello Russo, Agostino Mattera, Amato Santoro and 10 more

Registry-linked trialOpen access · hybridAbstract read
In one paragraph

Article in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02275637 (Arrhythmias Detection in a Real World Population), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02275637 recruitingnot on this map

Arrhythmias Detection in a Real World Population: the RHYTHM DETECT Registry

TypeobservationalSponsorFondazione IRCCS Policlinico San Matteo di PaviaRan2014 to 2028Enrolled10,000ConditionsAppropriate and Inappropriate Shock Therapy With ICD, Arrhythmias DetectionArmsimplantable cardioverter defibrillator
3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
  3. Performance of a multi-sensor implantable defibrillator algorithm for heart failure monitoring in the presence of atrial fibrillation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors at 12 institutions in 2 countries.

Matteo BertiniCardiology Unit, Sant'Anna University Hospital, University of Ferrara, Via A. Moro 8, Ferrara 44121, Italy.ORCID 0000-0002-5285-7140
Francesco VitaliCardiology Unit, Sant'Anna University Hospital, University of Ferrara, Via A. Moro 8, Ferrara 44121, Italy.ORCID 0000-0002-0667-7616
Antonio D'OnofrioUnità Operativa di Elettrofisiologia, Studio e Terapia delle Aritmie', Monaldi Hospital, Via Leonardo Bianchi, 80131 Napoli (NA), Italy.ORCID 0000-0002-8739-5572
Gennaro VitulanoCardiology Unit, OO.RR. San Giovanni di Dio Ruggi d'Aragona, Largo Città d'Ippocrate, 84131 Salerno (SA), Italy.
Leonardo CalòCardiology Unit, Policlinico Casilino, Via Casilina, 1049, 00169 Roma (RM), Italy.ORCID 0000-0002-6062-5286
Gianluca SavareseCardiology Unit, S. Giovanni Battista Hospital, Via Massimo Arcamone, 06034 Foligno (PG), Italy.
Vincenzo Ezio SantobuonoCardiology Unit, University of Bari, Policlinico di Bari, Piazza Giulio Cesare, 11, 70124 Bari (BA), Italy.ORCID 0000-0002-8746-729X
Antonio Dello RussoClinica di Cardiologia e Aritmologia, Università Politecnica delle Marche, 'Ospedali Riuniti', Via Conca, 71, 60126 Torrette (AN), Italy.ORCID 0000-0001-7737-421X
Agostino MatteraCardiology Unit, S. Anna e S. Sebastiano Hospital, Via Ferdinando Palasciano, 81100 Caserta (CE), Italy.
Amato SantoroCardiology Unit, Azienda Ospedaliera Universitaria Senese, V.le Mario Bracci, 11, 53100 Siena (SI), Italy.ORCID 0000-0002-2629-4372
Raimondo CalvaneseCardiology Unit, Ospedale del Mare, ASL NA1, Via Enrico Russo, 11, 80147 Napoli (NA), Italy.ORCID 0000-0002-2002-5024
Giuseppe ArenaCardiology Unit, Ospedale Civile Apuane, Via Enrico Mattei, 21, 54100 Massa (MS), Italy.ORCID 0000-0002-0266-6493
Claudia AmelloneCardiology Unit, 'Maria Vittoria' Hospital, Via Luigi Cibrario, 72, 10144 Torino (TO), Italy.
Matteo ZiacchiInstitute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Via Giuseppe Massarenti, 9, 40138 Bologna (BO), Italy.ORCID 0000-0003-3617-2739
Pietro PalmisanoCardiology Unit, Ospedale 'G. Panico', Tricase, Via San Pio X, 4, 73039 Tricase (LE), Italy.ORCID 0000-0001-6705-6218
Luca SantiniCardiology Unit, 'Giovan Battista Grassi' Hospital, Via Gian Carlo Passeroni, 28, 00122 Lido di Ostia (RM), Italy.ORCID 0000-0001-9048-2039
Andrea MazzaCardiology Division, S. Maria della Stella Hospital, Località Ciconia, 05018 Orvieto (TR), Italy.ORCID 0000-0001-5519-8278
Monica CampariBoston Scientific, Viale Enrico Forlanini, 21, 20134 Milano (MI), Italy.
Sergio ValsecchiBoston Scientific, Viale Enrico Forlanini, 21, 20134 Milano (MI), Italy.ORCID 0000-0001-7055-6942
Giuseppe BorianiCardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo, 71, 41125 Modena (MO), Italy.ORCID 0000-0002-9820-4815
Azienda Ospedaliero Universitaria San Giovanni Battista · ITBoston Scientific (United States) · USUniversity of Ferrara · ITAzienda Ospedaliera Universitaria Senese · ITIRCCS Azienda Ospedliero-Universitaria di Bologna Policlinico di Sant'Orsola · ITMarche Polytechnic University · ITOspedale Maria Vittoria · ITOspedale Monaldi · ITOspedali Riuniti San Giovanni di Dio e Ruggi d'Aragona · ITPoliclinico Casilino · ITUniversity of Bari Aldo Moro · ITUniversity of Modena and Reggio Emilia · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsPatients with atrial fibrillation frequently experience sleep disorder breathing, and both conditions are highly prevalent in presence of heart failure (HF). We explored the association between the combination of an HF and a sleep apnoea (SA) index and the incidence of atrial high-rate events (AHRE) in patients with implantable defibrillators (ICDs). METHODS AND

resultsData were prospectively collected from 411 consecutive HF patients with ICD. The IN-alert HF state was measured by the multi-sensor HeartLogic Index (>16), and the ICD-measured Respiratory Disturbance Index (RDI) was computed to identify severe SA. The endpoints were as follows: daily AHRE burden of ≥5 min, ≥6 h, and ≥23 h. During a median follow-up of 26 months, the time IN-alert HF state was 13% of the total observation period. The RDI value was ≥30 episodes/h (severe SA) during 58% of the observation period. An AHRE burden of ≥5 min/day was documented in 139 (34%) patients, ≥6 h/day in 89 (22%) patients, and ≥23 h/day in 68 (17%) patients. The IN-alert HF state was independently associated with AHRE regardless of the daily burden threshold: hazard ratios from 2.17 for ≥5 min/day to 3.43 for ≥23 h/day (P < 0.01). An RDI ≥ 30 episodes/h was associated only with AHRE burden ≥5 min/day [hazard ratio 1.55 (95% confidence interval: 1.11-2.16), P = 0.001]. The combination of IN-alert HF state and RDI ≥ 30 episodes/h accounted for only 6% of the follow-up period and was associated with high rates of AHRE occurrence (from 28 events/100 patient-years for AHRE burden ≥5 min/day to 22 events/100 patient-years for AHRE burden ≥23 h/day).

conclusionsIn HF patients, the occurrence of AHRE is independently associated with the ICD-measured IN-alert HF state and RDI ≥ 30 episodes/h. The coexistence of these two conditions occurs rarely but is associated with a very high rate of AHRE occurrence. CLINICAL

trial registrationURL: http://clinicaltrials.gov/Identifier: NCT02275637.

Indexed as

Atrial FibrillationDefibrillators, ImplantableHeart FailureSleep Apnea SyndromesHumansRisk AssessmentAtrial fibrillationHeart failureImplantable defibrillatorRisk stratificationSleep apnoea

Identifiers

PMID36881780
PMCPMC10105876
OpenAlexW4323351487

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.