ArticleCureus2023
Functional Outcomes of Anterior Cruciate Ligament Reconstruction Using Titanium Adjustable Loop Button and Poly-L-co-DL-Lactic Acid-Beta Tricalcium Phosphate (PLDLA-bTCP) Interference Screws: A Single-Center, Retrospective, Observational Study.
Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 7 citations in OpenAlex.
- Effect of Different Screw Materials on ACL Reconstruction With the Tape Locking Screw Technique: A Retrospective Study From the FAST Cohort.Orthopaedic journal of sports medicine · 2024Article
- Article
- Article
- Article
- Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background The anterior cruciate ligament (ACL) reconstruction is a standard surgery in patients with instability of the knee caused by ACL insufficiency. Several differential procedures using grafts and implants such as loops, buttons, and screws have been described. This study aimed to assess the functional outcomes of ACL reconstruction surgery using titanium adjustable loop buttons and poly-L-co-DL-lactic acid-beta tricalcium phosphate (PLDLA-bTCP) interference screws. Methodology This was a retrospective, observational, single-center, and clinical study. A total of 42 patients who underwent ACL reconstruction at a tertiary trauma center in northern India between 2018 and 2022 were recruited. Data including demographics, details of the injury, surgery, implants, and surgical outcomes were collected from the patients' medical records. Further, post-surgery details such as re-injury, adverse events, International Knee Documentation Committee (IKDC) profiles, and Lysholm knee score were recorded from the enrolled patients through a telephonic follow-up. Pain score and Tegner activity scale were used to compare the knee status before and after surgery. Results At the time of surgery, the mean age of the recruited patients was 31.1 ± 8.8 years, with a male preponderance of 93%. About 57% of patients had left knee injuries. The common symptoms were instability (67%), pain (62%), swelling (14%), and giving away (5%). During surgery, titanium adjustable loop button and PLDLA-bTCP interference screw implants were used in all patients. The mean follow-up time was 21.2 ± 14.2 months. Based on patient responses, the mean IKDC and Lysholm scores were found to be 54.02 ± 5.93 and 94.4 ± 4.73, respectively. Further, the proportion of patients reporting pain decreased from 62% before surgery to 21% after surgery. The mean Tegner score revealed a significant increase in the activity levels of the patients post-surgery compared to pre-surgery (p < 0.05). Lastly, no adverse events or re-injuries were reported in any of the patients during follow-up. Conclusions Our findings revealed a significant improvement in Tegner activity levels and pain scores after surgery. In addition, patient-reported IKDC and Lysholm scores fell under the category of good knee status and function, suggesting a satisfactory functional outcome of ACL reconstruction. Hence, titanium adjustable loop and PLDLA-bTCP interference screws may be a good choice of implants for successful ACL reconstruction surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.