Evidence map›Paper›PMID 36879028›Full record

Trial reportScientific reports2023

The biomechanical effect of fibular strut grafts on humeral surgical neck fractures with lateral wall comminution.

Hsien-Hao Chang, Joon-Ryul Lim, Kil-Han Lee, Haemosu An, Tae-Hwan Yoon, Yong-Min Chun

Erratum issuedOpen access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Hsien-Hao ChangDepartment of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea.
Joon-Ryul LimDepartment of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea.
Kil-Han LeeDepartment of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea.
Haemosu AnDepartment of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea.
Tae-Hwan YoonDepartment of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea.
Yong-Min ChunDepartment of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea. min1201@hanmail.net.
Severance Hospital · KRYonsei University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

No studies have evaluated the effect of fibular strut augmentation on the stability of locking plate fixation for osteoporotic proximal humeral fractures with lateral wall comminution. The purpose of this study was to evaluate the stability of locking plate fixation with a fibular strut graft compared with locking plate alone in an osteoporotic two-part surgical neck fracture model with lateral cortex comminution. Ten paired fresh-frozen cadaveric humeri were randomly allocated into two groups, either the locking plate alone (LP group) or locking plate with fibular strut graft augmentation (LPFSG group), with an equal number of right and left osteoporotic surgical neck fractures with lateral wall comminution of the greater tuberosity. Varus, internal/external torsion, and axial compression stiffness as well as single load to failure were measured in plate-bone constructs, and the LPFSG group showed significantly greater values in all metrics. In conclusion, this biomechanical study shows that fibular strut augmentation significantly enhances varus stiffness, internal torsion stiffness, external torsion stiffness, and maximum failure load of a construct compared to locking plate fixation alone in proximal humeral fractures with lateral wall comminution.

Indexed as

Osteoporotic FracturesShoulder FracturesBenchmarkingEpiphysesHumansHumerus

Identifiers

PMID36879028
PMCPMC9988971
OpenAlexW4323310849

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked