Evidence map›Paper›PMID 36877708›Full record

ArticlePloS one2023

Comparison between passive knee kinematics during surgery and active knee kinematics during walking: A preliminary study.

Xavier Gasparutto, Alice Bonnefoy-Mazure, Michael Attias, Raphaël Dumas, Stéphane Armand, Hermès Miozzari

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Xavier GasparuttoKinesiology Laboratory, Geneva University Hospitals and University of Geneva, Geneva, Switzerland.ORCID 0000-0001-8617-6522
Alice Bonnefoy-MazureKinesiology Laboratory, Geneva University Hospitals and University of Geneva, Geneva, Switzerland.
Michael AttiasSchool of Health Sciences, University of Applied Sciences and Arts Western Switzerland (HES-SO), Geneva, Switzerland.
Raphaël DumasClaude Bernard University Lyon 1 and Gustave Eiffel University, LBMC UMR_T9406, University of Lyon and Laboratory of Biomechanics and Impact Mechanics, Lyon, France.ORCID 0000-0002-0368-8248
Stéphane ArmandKinesiology Laboratory, Geneva University Hospitals and University of Geneva, Geneva, Switzerland.
Hermès MiozzariDepartment of Orthopaedic Surgery and Trauma Care, Geneva University Hospitals, Geneva, Switzerland.
University of Geneva · CHHES-SO University of Applied Sciences and Arts Western Switzerland · CHHôpital Beau-Séjour · CHUniversité Claude Bernard Lyon 1 · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recovery of function is among a patient's main expectations when undergoing total knee arthroplasty (TKA). However, normal gait knee function is not always completely restored, which can affect patient satisfaction and quality of life. Computer-assisted surgery (CAS) allows surgeons to evaluate passive knee kinematics intra-operatively. Understanding associations between knee kinematics measured during surgery and during daily activities, such as walking, could help define criteria for success based on knee function and not only on the correct alignment of the implant or the leg. This preliminary study compared passive knee kinematics measured during surgery with active kinematics measured during walking. Eight patients underwent a treadmill gait analysis using the KneeKG™ system both before surgery and three months afterwards. Knee kinematics were measured during CAS both before and after TKA implantation. The anatomical axes of the KneeKG™ and CAS systems were homogenised using a two-level, multi-body kinematics optimisation with a kinematic chain based on the calibration measured during CAS. A Bland-Altman analysis was performed before and after TKA for adduction-abduction angle, internal-external rotation, and anterior-posterior displacement over the whole gait cycle, at the single stance phase and at the swing phase. Homogenising the anatomical axes between CAS and treadmill gait led to limited median bias and limits of agreement (post-surgery -0.6 ± 3.6 deg, -2.7 ± 3.6 deg, and -0.2 ± 2.4 mm for adduction-abduction, internal-external rotation and anterior-posterior displacement, respectively). At the individual level, correlations between the two systems were mostly weak (R2 < 0.3) over the whole gait cycle, indicating low kinematic consistency between the two measurements. However, correlations were better at the phase level, especially the swing phase. The multiple sources of differences did not enable us to conclude whether they came from anatomical and biomechanical differences or from measurement system errors.

Indexed as

Knee JointQuality of LifeBiomechanical PhenomenaGaitHumansWalking

Identifiers

PMID36877708
PMCPMC9987822
OpenAlexW4323294186

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.