Evidence map›Paper›PMID 36877450›Full record

ArticleCardiovascular engineering and technology2023

In Silico Evaluation of a Self-powered Venous Ejector Pump for Fontan Patients.

Reza Rasooli, Knut Erik Teigen Giljarhus, Aksel Hiorth, Ingunn Westvik Jolma, Jan Ludvig Vinningland, Charlotte de Lange, Henrik Brun, Henrik Holmstrom

Open access · hybridAbstract read
In one paragraph

Article in Cardiovascular engineering and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Reza RasooliDepartment of Energy Resources, Faculty of Science and Technology, University of Stavanger, 4036, Stavanger, Norway. reza.rasooli@uis.no.ORCID 0000-0003-0071-2908
Knut Erik Teigen GiljarhusDepartment of Mechanical and Structural Engineering and Materials Science, University of Stavanger, 4036, Stavanger, Norway.
Aksel HiorthDepartment of Energy Resources, Faculty of Science and Technology, University of Stavanger, 4036, Stavanger, Norway.
Ingunn Westvik JolmaDepartment of Chemistry, Bioscience and Environmental Engineering, University of Stavanger, 4036, Stavanger, Norway.
Jan Ludvig VinninglandNorwegian Research Center (NORCE), Oslo, Norway.
Charlotte de LangeDepartment of Paediatric Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden.
Henrik BrunSection for Medical Cybernetics and Image Processing, The Intervention Centre, Oslo University Hospital Rikshospitalet, Oslo, Norway.
Henrik HolmstromDepartment of Paediatric Cardiology, Division of Paediatric and Adolescent Medicine, Oslo University Hospital, Oslo, Norway.
University of Stavanger · NOOslo University Hospital · NONORCE Research AS · NOSahlgrenska University Hospital · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe Fontan circulation carries a dismal prognosis in the long term due to its peculiar physiology and lack of a subpulmonic ventricle. Although it is multifactorial, elevated IVC pressure is accepted to be the primary cause of Fontan's high mortality and morbidity. This study presents a self-powered venous ejector pump (VEP) that can be used to lower the high IVC venous pressure in single-ventricle patients.

methodsA self-powered venous assist device that exploits the high-energy aortic flow to lower IVC pressure is designed. The proposed design is clinically feasible, simple in structure, and is powered intracorporeally. The device's performance in reducing IVC pressure is assessed by conducting comprehensive computational fluid dynamics simulations in idealized total cavopulmonary connections with different offsets. The device was finally applied to complex 3D reconstructed patient-specific TCPC models to validate its performance.

resultsThe assist device provided a significant IVC pressure drop of more than 3.2 mm Hg in both idealized and patient-specific geometries, while maintaining a high systemic oxygen saturation of more than 90%. The simulations revealed no significant caval pressure rise (< 0.1 mm Hg) and sufficient systemic oxygen saturation (> 84%) in the event of device failure, demonstrating its fail-safe feature.

conclusionsA self-powered venous assist with promising in silico performance in improving Fontan hemodynamics is proposed. Due to its passive nature, the device has the potential to provide palliation for the growing population of patients with failing Fontan.

Indexed as

Fontan ProcedureHeart-Assist DevicesHeart Defects, CongenitalHeart VentriclesHemodynamicsHumansModels, CardiovascularPulmonary ArteryVena Cava, InferiorComputational fluid dynamicsCongenital heart diseaseFontan hemodynamicsFontan venous assistSingle-ventricle physiologySystemic venous hypertension

Identifiers

PMID36877450
PMCPMC10412470
OpenAlexW4323295313

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.