Observational studyPhysical and engineering sciences in medicine2023
Fluoroscopically guided vascular and cardiac transcatheter procedures: a comparison of occupational and patient dose by anatomical region.
Observational study in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 6 citations in OpenAlex.
- Consequences of ionizing radiation exposure to the cardiovascular system.Nature reviews. Cardiology · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
X-ray guided procedures are being performed by an increasing variety of medical specialties. Due to improvements in vascular transcatheter therapies, there is an increasing overlap of imaged anatomy between medical specialties. There is concern that non-radiology fluoroscopic operators may not have sufficient training to be well informed of the potential implications of radiation exposure and mitigation strategies to reduce dose. This was a prospective, observational, single center study to compare occupational and patient dose levels when imaging different anatomical regions during fluoroscopically guided cardiac and endovascular procedures. Occupational radiation dose was measured at the level of the temple of 24 cardiologists and 3 vascular surgeons (n = 1369), 32 scrub nurses (n = 1307) and 35 circulating nurses (n = 885). The patient dose was recorded for procedures (n = 1792) performed in three angiography suites. Abdominal imaging during endovascular aneurysm repair (EVAR) procedures was associated with a comparatively high average patient, operator and scrub nurse dose despite additional table-mounted lead shields. Air kerma was relatively high for procedures performed in the chest, and chest + pelvis. Higher dose area product and staff eye dose were recorded during procedures of the chest + pelvis due to the use of digital subtraction angiography to evaluate access route prior to/during transaortic valve implantation. Scrub nurses were exposed to higher average radiation levels than the operator during some procedures. Staff should be cognizant of the potentially higher radiation burden to patients and exposed personnel during EVAR procedures and cardiac procedures using digital subtraction angiography.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.