ArticleJournal of sports science & medicine2023
Reliability of Soft Tissue Vibration Measurement and Number of Steps Demanded during Treadmill Running.
Article in Journal of sports science & medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Assessment of Xsens Motion Trackers' Accuracy to Measure Induced Vibrations During Endurance Running.Journal of functional morphology and kinesiology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The present study aims to determine the test-retest reliability of the input signal (INPUT) of foot impact and soft tissue vibration (STV) of the lower limb muscles during treadmill running. Twenty-six recreational runners participated in three running trials at constant velocity (10 km/h) within two days. The INPUT and STV of gastrocnemius medialis (GAS) and vastus lateralis (VL) were extracted from 100 steps measured by three triaxial accelerometers. The Intraclass Correlation Coefficient (ICC) was calculated to determine the Intra-trial and Inter-day reliability of the different variables. Intra-trial reliability results indicated that most of the INPUT and GAS STV parameters, except for damping coefficient and setting time, have good to excellent reliability (0.75 < ICC < 0.9) from the beginning of the run (10 steps) to the end. In contrast, only 4 VL STV parameters showed good reliability. Furthermore, inter-trial reliability measured on day one showed that the number of reliable parameters reduced, especially for VL STV, and more steps were required (20 < steps < 80) to achieve good reliability. Inter-day reliability results showed that only one VL STV parameter reached good reliability. Therefore, the present results show that the measurement of the foot impact and the calf muscle vibrations present a good to excellent reliability measured on a single trial and two trials carried out on the same day. The reliability of these parameters remains good when comparing two days of experimentation. We recommend measuring impact and STV parameters during treadmill running in the same session.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.