Evidence map›Paper›PMID 36875750›Full record

ArticleJournal of healthcare engineering2023

Edge-Enabled Heart Rate Estimation from Multisensor PPG Signals.

Xingchi Chen, Fa Zhu, Hai Zhao

RetractedAbstract readRetracted Publication
In one paragraph

Article in Journal of healthcare engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Xingchi ChenSchool of Computer Science and Engineering, Northeastern University, Shenyang 110819, China.ORCID 0000-0003-4345-3440
Fa ZhuCollege of Information Science and Technology, Nanjing Forestry University, Nanjing 210037, China.ORCID 0000-0002-7089-5386
Hai ZhaoSchool of Computer Science and Engineering, Northeastern University, Shenyang 110819, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Heart rate (HR) estimation from multisensor PPG signals suffers from the dilemma of inconsistent computation results, due to the prevalence of bio-artifacts (BAs). Furthermore, advancements in edge computing have shown promising results from capturing and processing diversified types of sensing signals using the devices of Internet of Medical Things (IoMT). In this paper, an edge-enabled method is proposed to estimate HRs accurately and with low latency from multisensor PPG signals captured by bilateral IoMT devices. First, we design a real-world edge network with several resource-constrained devices, divided into collection edge nodes and computing edge nodes. Second, a self-iteration RR interval calculation method, at the collection edge nodes, is proposed leveraging the inherent frequency spectrum feature of PPG signals and preliminarily eliminating the influence of BAs on HR estimation. Meanwhile, this part also reduces the volume of sent data from IoMT devices to compute edge nodes. Afterward, at the computing edge nodes, a heart rate pool with an unsupervised abnormal detection method is proposed to estimate the average HR. Experimental results show that the proposed method outperforms traditional approaches which rely on a single PPG signal, attaining better results in terms of the consistency and accuracy for HR estimation. Furthermore, at the designed edge network, our proposed method processes a 30 s PPG signal to obtain an HR, consuming only 4.24 s of computation time. Hence, the proposed method is of significant value for the low-latency applications in the field of IoMT healthcare and fitness management.

Indexed as

ArtifactsExerciseHeart RateHealth FacilitiesHumansInternet

Identifiers

PMID36875750
PMCPMC9977552

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.