HoloLens augmented reality system for transperineal free-hand prostate procedures.

Ming Li, Sherif Mehralivand, Sheng Xu, Nicole Varble, Ivane Bakhutashvili, Sandeep Gurram, Peter A Pinto, Peter L Choyke, Bradford J Wood, Baris Turkbey

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ming LiNational Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, Maryland, United States.
Sherif MehralivandNational Institutes of Health, Molecular Imaging Branch, National Cancer Institute, Bethesda, Maryland, United States.ORCID https://orcid.org/0000-0003-1405-3683
Sheng XuNational Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, Maryland, United States.
Nicole VarbleNational Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, Maryland, United States.
Ivane BakhutashviliNational Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, Maryland, United States.
Sandeep GurramNational Institutes of Health, Urologic Oncology Branch, National Cancer Institute, Bethesda, Maryland, United States.ORCID https://orcid.org/0000-0002-6405-9269
Peter A PintoNational Institutes of Health, Urologic Oncology Branch, National Cancer Institute, Bethesda, Maryland, United States.
Peter L ChoykeNational Institutes of Health, Molecular Imaging Branch, National Cancer Institute, Bethesda, Maryland, United States.ORCID https://orcid.org/0000-0003-1086-8826
Bradford J WoodNational Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, Maryland, United States.ORCID https://orcid.org/0000-0002-4297-0051
Baris TurkbeyNational Institutes of Health, Molecular Imaging Branch, National Cancer Institute, Bethesda, Maryland, United States.

Funding

Center for Interventional OncologyZIDBC011242 · NCI · DIVISION OF BASIC SCIENCES - NCI · PI WOOD, BRADFORD J · 2009 to 2025
$18.7M
Intramural NIH HHS ZID BC011242
6 · The paper itself

Abstract

Purpose: An augmented reality (AR) system was developed to facilitate free-hand real-time needle guidance for transperineal prostate (TP) procedures and to overcome the limitations of a traditional guidance grid. Approach: The HoloLens AR system enables the superimposition of annotated anatomy derived from preprocedural volumetric images onto a patient and addresses the most challenging part of free-hand TP procedures by providing real-time needle tip localization and needle depth visualization during insertion. The AR system accuracy, or the image overlay accuracy ( Results: The image overlay error was Conclusions: The HoloLens AR system can provide accurate needle guidance for TP interventions. AR support for free-hand lesion targeting is feasible and may provide more flexibility than grid-based methods, due to the real-time 3D and immersive experience during free-hand TP procedures.

Indexed as

augmented realityHoloLens guidanceinterventional radiologymedical imagingpercutaneous proceduretransperineal prostate procedure

Identifiers

PMID36875636
PMCPMC9976411

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.