A method for beam's eye view breath-hold monitoring during breast volumetric modulated arc therapy.

M A Carr, M Gargett, C Stanton, B Zwan, H L Byrne, J T Booth

Open access · goldAbstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

M A CarrNorthern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales, Australia.
M GargettNorthern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales, Australia.
C StantonNorthern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales, Australia.
B ZwanCentral Coast Cancer Centre, Gosford Hospital, Gosford, New South Wales, Australia.
H L ByrneACRF Image-X Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.
J T BoothNorthern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales, Australia.
The University of Sydney · AUGosford Hospital · AURoyal North Shore Hospital · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Deep inspiration breath-hold (DIBH) is a technique that is widely utilised to spare the heart and lungs during breast radiotherapy. In this study, a method was developed to validate directly the intrafraction accuracy of DIBH during breast volumetric modulated arc therapy (VMAT) via internal chest wall (CW) monitoring. Materials and methods: In-house software was developed to automatically extract and compare the treatment position of the CW in cine-mode electronic portal image device (EPID) images with the planned CW position in digitally reconstructed radiographs (DRR) for breast VMAT treatments. Feasibility of this method was established by evaluating the percentage of total dose delivered to the target volume when the CW was sufficiently visible for monitoring. Geometric accuracy of the approach was quantified by applying known displacements to an anthropomorphic thorax phantom. The software was used to evaluate (offline) the geometric treatment accuracy for ten patients treated using real-time position management (RPM)-guided DIBH. Results: The CW could be monitored within the tangential sub-arcs which delivered a median 89% (range 73% to 97%) of the dose to target volume. The phantom measurements showed a geometric accuracy within 1 mm, with visual inspection showing good agreement between the software-derived and user-determined CW positions. For the RPM-guided DIBH treatments, the CW was found to be within ±5 mm of the planned position in 97% of EPID frames in which the CW was visible. Conclusion: An intrafraction monitoring method with sub-millimetre accuracy was successfully developed to validate target positioning during breast VMAT DIBH.

Indexed as

BEV monitoringBreast VMATChest wallCine EPIDDeep inspiration breath-holdDIBHElectronic portal imaging deviceIntrafraction motion

Identifiers

PMID36875326
PMCPMC9975298
OpenAlexW4319994268

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.