Evidence map›Paper›PMID 36874558›Full record

ArticleThe Journal of innovations in cardiac rhythm management2023

Loss of His-bundle and Right Ventricular Septal Capture Following Transcatheter Aortic Valve Replacement-A Case Report.

Abdullah Asreb, Joon Ahn

Open access · diamondAbstract readCase Reports
In one paragraph

Article in The Journal of innovations in cardiac rhythm management, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 94% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Abdullah AsrebInternal Medicine Residency, Northeast Georgia Medical Center, Gainesville, GA, USA.
Joon AhnCardiac Electrophysiology, Northeast Georgia Medical Center, Gainesville, GA, USA.
Northeast Georgia Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Conduction abnormalities following transcatheter aortic valve replacement (TAVR) are common. High-grade atrioventricular block (AVB) and new-onset left bundle branch block remain the most reported. These often require the placement of a permanent pacemaker (PPM). His-bundle (HB) pacing is increasingly being utilized as the preferred mode of ventricular pacing due to its more physiologic ventricular activation. In this case report, we present a case of a patient who developed loss of HB capture and experienced an increase in the local right ventricular (RV) capture threshold after TAVR that led to unrecognized intermittent loss of ventricular capture and symptoms. An 80-year-old man with severe aortic stenosis presented with symptomatic bradycardia due to typical atrial flutter (AFL) with a high-grade AVB and an underlying right bundle branch block. He underwent placement of a dual-chamber PPM (Medtronic, Inc., Minneapolis, MN, USA) with a HB pacing lead. HB mapping demonstrated a normal H-V interval, and the lead was fixated with non-selective HB capture. The R-waves measured 2.8 mV, the pacing impedance was 544 Ω, and the non-selective HB and local RV capture threshold was 0.5 V @ 1 ms. He underwent AFL ablation, and his atrial leads were normal. He subsequently underwent successful TAVR with a 29-mm Sapien 3 valve (Edwards Lifesciences, Irvine, CA, USA). Post-TAVR, PPM interrogation showed a loss of HB capture with a left bundle paced QRS morphology. Following discharge, he presented with stroke-like symptoms and was noted to have intermittent loss of RV capture with complete heart block (CHB) and a slow ventricular escape rhythm. PPM interrogation revealed an elevated pacing threshold, and his RV output was gradually increased to a maximum output of 7.5 V @ 1.5 ms. He also developed a fever and was found to have enterococcal bacteremia. Transesophageal echocardiography demonstrated vegetations on his prosthetic valve and pacemaker lead, without a perivalvular abscess. He underwent explantation of the pacemaker system and insertion of a temporary PPM. After intravenous antibiotic therapy with negative blood cultures, he underwent re-implantation of a new right-sided dual-chamber PPM, and an RV pacing lead was placed into the RV outflow tract. HB pacing is becoming the preferred mode of physiologic ventricular pacing. This case illustrates the potential risks of the TAVR procedure in patients with existing HB pacing leads. We observed a loss of HB capture and the development of CHB due to traumatic injury to the HB distal to the HB pacing lead after TAVR placement together with an increase in the local RV capture threshold. The depth of TAVR placement is an important aspect of the TAVR procedure that determines the risk of developing CHB and may also affect the HB and local RV pacing thresholds post-procedure.

Indexed as

Complete heart blockHis bundleleft bundle branch blocktranscatheter aortic valve replacement

Identifiers

PMID36874558
PMCPMC9983619
OpenAlexW4323293778

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.