Evidence map›Paper›PMID 36874483›Full record

ArticleBiomedical optics express2023

Signal restoration algorithm for photoacoustic imaging systems.

Soheil Hakakzadeh, Mohammadreza Amjadian, Yachao Zhang, Seyed Masood Mostafavi, Zahra Kavehvash, Lidai Wang

Abstract read
In one paragraph

Article in Biomedical optics express, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Soheil HakakzadehElectrical Engineering Department of Sharif University of Technology, Tehran, Iran.ORCID https://orcid.org/0000-0002-6791-1031
Mohammadreza AmjadianElectrical Engineering Department of Sharif University of Technology, Tehran, Iran.
Yachao ZhangDepartment of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR, China.ORCID https://orcid.org/0000-0002-1150-8745
Seyed Masood MostafaviElectrical Engineering Department of Sharif University of Technology, Tehran, Iran.ORCID https://orcid.org/0000-0003-1701-8154
Zahra KavehvashElectrical Engineering Department of Sharif University of Technology, Tehran, Iran.ORCID https://orcid.org/0000-0002-7636-6100
Lidai WangDepartment of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In a photoacoustic (PA) imaging system, the detectors are bandwidth-limited. Therefore, they capture PA signals with some unwanted ripples. This limitation degrades the resolution/contrast and induces sidelobes and artifacts in the reconstructed images along the axial direction. To compensate for the limited bandwidth effect, we present a PA signal restoration algorithm, where a mask is designed to extract the signals at the absorber positions and remove the unwanted ripples. This restoration improves the axial resolution and contrast in the reconstructed image. The restored PA signals can be considered as the input of the conventional reconstruction algorithms (e.g., Delay-and-sum (DAS) and Delay-multiply-and-sum (DMAS)). To compare the performance of the proposed method, DAS and DMAS reconstruction algorithms were performed with both the initial and restored PA signals on numerical and experimental studies (numerical targets, tungsten wires, and human forearm). The results show that, compared with the initial PA signals, the restored PA signals can improve the axial resolution and contrast by 45% and 16.1 dB, respectively, and suppress background artifacts by 80%.

Identifiers

PMID36874483
PMCPMC9979682

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.