ArticleFrontiers in oncology2023
Development of novel biliary metal stent with coil-spring structure and its application
Article in Frontiers in oncology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- Advances in functional coatings on biliary stents.Regenerative biomaterials · 2024Review
- The past, present, and future of endoscopic management for biliary strictures: technological innovations and stent advancements.Frontiers in medicine · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: As of date, endoscopic biliary stenting with plastic stent (PS) and self-expandable metal stent (SEMS) have been widely used for the palliation of biliary tract strictures. However, these two stents have several limitations regarding the management of biliary strictures caused by intrahepatic and hilar cholangiocarcinoma. PS has short patency and also risks bile duct injury and bowel perforation. SEMS is difficult to revise when occluded by tumor overgrowth. To compensate for such shortcomings, we developed a novel biliary metal stent with coil-spring structure. The aim of this study was to investigate the feasibility and efficacy of the novel stent in a swine model. Methods: The biliary stricture model was prepared in six mini-pigs using endobiliary radiofrequency ablation. Conventional PS (n=2) and novel stents (n=4) were deployed endoscopically. Technical success was defined as successful stent placement and clinical success was defined as >50% reduction of serum bilirubin level. Adverse events, stent migration, and endoscopic removability for one month after stenting were also assessed. Results: The biliary stricture was successfully created in all animals. The technical success rate was 100 %, and the clinical success rate was 50% in the PS group and 75% in the novel stent group. In the novel stent group, the median pre- and post-treatment serum bilirubin levels were 3.94 and 0.3 mg/dL. Stent migration occurred in two pigs and two stents were removed by endoscopy. There was no stent-related mortality. Conclusions: The newly designed biliary metal stent was feasible and effective in a swine biliary stricture model. Further studies are needed to verify the usefulness of the novel stent in the management of biliary strictures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.