Evidence map›Paper›PMID 36866033›Full record

ArticleIEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division2022

Multiphysical Analytical Modeling and Design of A Magnetically Steerable Robotic Catheter for Treatment of Peripheral Artery Disease.

Yang Liu, Tarunraj G Mohanraj, Mohammad R Rajebi, Lei Zhou, Farshid Alambeigi

Open access · greenAbstract read
In one paragraph

Article in IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Yang LiuWalker Department of Mechanical Engineering and the Texas Robotics at the University of Texas at Austin, Austin, TX, 78712, USA.
Tarunraj G MohanrajWalker Department of Mechanical Engineering and the Texas Robotics at the University of Texas at Austin, Austin, TX, 78712, USA.
Mohammad R RajebiVascual and Interventional Radiology Section of Christus Spohn Hospital, Corpus Christi, TX, 78404, USA.
Lei ZhouWalker Department of Mechanical Engineering and the Texas Robotics at the University of Texas at Austin, Austin, TX, 78712, USA.
Farshid AlambeigiWalker Department of Mechanical Engineering and the Texas Robotics at the University of Texas at Austin, Austin, TX, 78712, USA.
Walker (United States) · USCHRISTUS Spohn Hospital Corpus Christi - Memorial · US

Funding

A Neurosurgical Robotic System for Minimally Invasive Spinal Fusion of Osteoporotic Vertebrae Using Flexible Pedicle ScrewsR21EB030796 · NIBIB · UNIVERSITY OF TEXAS AT AUSTIN · PI ALAMBEIGI, FARSHID · 2021 to 2023
$607k
NIBIB NIH HHS R21 EB030796
6 · The paper itself

Abstract

This article presents a unique multiphysical analytical modeling framework and solution algorithm to provide an effective tool for design of magnetically steerable robotic catheters (MSRCs) experiencing external interaction loads. Particularly, in this study, we are interested in design and fabrication of a MSRC with flexural patterns for treatment of peripheral artery disease (PAD). Aside from the parameters involved in the magnetic actuation system and the external interaction loads acting on the MSRC, the considered flexural patterns have a critical role on the deformation behavior and steerability of the proposed MSRC. Therefore, to optimally design such MSRC, we utilized the proposed multiphysical modeling approach and thoroughly evaluated the influence of involved parameters on the performance of the MSRC via two simulations studies. We also conducted experimental studies in a free bending condition and in the presence of different external interaction loads on two custom-designed MSRCs to thoroughly evaluate the efficacy of the proposed multiphysical model and solution algorithm. Our analysis demonstrates the accuracy of the proposed approach and necessity of utilizing such models to optimally design a MSRC before fabrication procedure.

Indexed as

Continuum RobotMedical Robots and SystemsModeling of Magnetically Steerable Catheter

Identifiers

PMID36866033
PMCPMC9974172
OpenAlexW4285270509

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.