ArticleOphthalmology and therapy2023
Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction.
Article in Ophthalmology and therapy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06278220 (Scheimpflug Versus Placido-disc System in Evaluation of Corneal Higher-Order Aberrations Before and After LASIK), which is not on this map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Scheimpflug Versus Placido-disc System in Evaluation of Corneal Higher-Order Aberrations Before and After LASIK
Who cites it
6 citing papers in PubMed.
- Agreement between Pentacam HR and Visionix VX650 system for corneal and anterior chamber parameters.BMC ophthalmology · 2026Article
- Visual and optical outcomes of pupilloplasty in glued intrascleral intraocular lens eyes with irregular mydriatic pupils.Indian journal of ophthalmology · 2026Observational
- Article
- Immediate Impact of Artificial Tear Composition on Optical Aberrations: A Comparative Study of Lipid and Non-Lipid Hydroxypropyl Guar Formulations.Ophthalmology and therapy · 2025Article
- Agreement between Scheimpflug-Placido topographer (SiriusInternational ophthalmology · 2025Article
- Repeatability assessment of anterior segment measurements in myopic patients using an anterior segment OCT with placido corneal topography and agreement with a swept-source OCT.BMC ophthalmology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
introductionThe aim of this study was to evaluate the measurements of corneal higher-order aberrations (HOAs) obtained by a new anterior segment optical coherence tomography (OCT) technique combined with a Placido topographer (the MS-39 device) in eyes with prior small-incision lenticule extraction (SMILE) and compare them to the measurements obtained by a Scheimpflug camera combined with a Placido topographer (the Sirius device).
methodsA total of 56 eyes (56 patients) were included in this prospective study. Corneal aberrations were analyzed for the anterior, posterior, and total cornea surfaces. Within-subject standard deviation (S
resultsHigh repeatability was observed for anterior and total corneal parameters, with S
conclusionThe MS-39 device achieved high precision in both anterior and total corneal measurements; the precision of posterior corneal higher-order RMS, astigmatism II, coma, and trefoil was lower. The two technologies used by the MS-39 and Sirius devices can be used interchangeably for measuring corneal HOAs after SMILE.
Indexed as