Evidence map›Paper›PMID 36861657›Full record

ArticleJournal of biomedical materials research. Part A2023

Polyacrylamide-based hydrogel coatings improve biocompatibility of implanted pump devices.

Doreen Chan, Caitlin L Maikawa, Andrea I d'Aquino, Shyam S Raghavan, Megan L Troxell, Eric A Appel

Abstract read
In one paragraph

Article in Journal of biomedical materials research. Part A, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Traceless Regulation of Genetic Circuitry.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  3. Article
  4. Article
  5. Membrane-Inserting α‑Lipid Polymers: Understanding Lipid Membrane Insertion and Effect on Membrane Fluidity.Chemistry of materials : a publication of the American Chemical Society · 2025
    Article
  6. Article
  7. Applications and prospects of biomaterials in diabetes management.Frontiers in bioengineering and biotechnology · 2025
    Review
  8. Article
  9. Review
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Doreen ChanDepartment of Chemistry, Stanford University, Stanford, California, USA.
Caitlin L MaikawaDepartment of Materials Science & Engineering, Stanford University, Stanford, California, USA.ORCID 0000-0002-6214-1226
Andrea I d'AquinoDepartment of Materials Science & Engineering, Stanford University, Stanford, California, USA.ORCID 0000-0002-4204-8219
Shyam S RaghavanDepartment of Pathology, Stanford University School of Medicine, Stanford, California, USA.
Megan L TroxellDepartment of Pathology, University of Virginia, Charlottesville, Virginia, USA.
Eric A AppelDepartment of Materials Science & Engineering, Stanford University, Stanford, California, USA.ORCID 0000-0002-2301-7126

Funding

Stanford Islet Research CoreP30DK116074 · NIDDK · STANFORD UNIVERSITY · PI Seung K Kim · 2017 to 2026
$19.5M
Co-Formulations of Amylin Analogues with Insulin Analogues for Treatment of DiabetesR01DK119254 · NIDDK · STANFORD UNIVERSITY · PI APPEL, ERIC ANDREW · 2019 to 2023
$2.9M
NIDDK NIH HHS P30 DK116074NIDDK NIH HHS R01 DK119254
6 · The paper itself

Abstract

The introduction of transcutaneous and subcutaneous implants and devices into the human body instigates fouling and foreign body responses (FBRs) that limit their functional lifetimes. Polymer coatings are a promising solution to improve the biocompatibility of such implants, with potential to enhance in vivo device performance and prolong device lifetime. Here we sought to develop novel materials for use as coatings on subcutaneously implanted devices to reduce the FBR and local tissue inflammation in comparison to gold standard materials such as poly(ethylene glycol) and polyzwitterions. We prepared a library of polyacrylamide-based copolymer hydrogels, which were selected from materials previously shown to exhibit remarkable antifouling properties with blood and plasma, and implanted them into the subcutaneous space of mice to evaluate their biocompatibility over the course of 1 month. The top performing polyacrylamide-based copolymer hydrogel material, comprising a 50:50 mixture of N-(2-hydroxyethyl)acrylamide (HEAm) and N-(3-methoxypropyl)acrylamide (MPAm), exhibited significantly better biocompatibility and lower tissue inflammation than gold standard materials. Moreover, when applied to polydimethylsiloxane disks or silicon catheters as a thin coating (45 ± 1 μm), this leading copolymer hydrogel coating significantly improved implant biocompatibility. Using a rat model of insulin-deficient diabetes, we showed that insulin pumps fitted with HEAm-co-MPAm hydrogel-coated insulin infusion catheters exhibited improved biocompatibility and extended functional lifetime over pumps fitted with industry standard catheters. These polyacrylamide-based copolymer hydrogel coatings have the potential to improve device function and lifetime, thereby reducing the burden of disease management for people regularly using implanted devices.

Indexed as

InflammationInsulinsAcrylamidesAnimalsHumansHydrogelsMicePolyacrylamidesPolymersRatsAcrylamidesHydrogelsInsulinsPolyacrylamidesPolymersbiocompatibilitydiabetesforeign body responsehydrogelsinsulin pump

Identifiers

PMID36861657
PMCPMC10161736

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.