Evidence map›Paper›PMID 36859708›Full record

ArticleScientific reports2023

Relationship between iliopsoas muscle surface pressure and implant alignment after total hip arthroplasty: a cadaveric study.

Yasuaki Tamaki, Tomohiro Goto, Joji Iwase, Keizo Wada, Yasuyuki Omichi, Daisuke Hamada, Yoshihiro Tsuruo, Koichi Sairyo

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yasuaki TamakiDepartment of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima, 770-8503, Japan. footballtravel0309@yahoo.co.jp.
Tomohiro GotoDepartment of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima, 770-8503, Japan.
Joji IwaseDepartment of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima, 770-8503, Japan.
Keizo WadaDepartment of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima, 770-8503, Japan.
Yasuyuki OmichiDepartment of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima, 770-8503, Japan.
Daisuke HamadaDepartment of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima, 770-8503, Japan.
Yoshihiro TsuruoDepartment of Anatomy and Cell Biology, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan.
Koichi SairyoDepartment of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima, 770-8503, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Iliopsoas impingement after total hip arthroplasty is caused by the implant irritating the iliopsoas muscle, but changes in the iliopsoas muscle have not been quantitatively evaluated. This study assessed changes in the surface pressure of the iliopsoas muscle when the implant alignment was varied. Total hip arthroplasty was performed in 10 fresh-frozen cadaveric hips. We evaluated the maximum and mean surface pressure of the iliopsoas muscle with the hip in 20° and 10° extension, the neutral position, and 10° flexion when the anterior cup protrusion length (ACPL), stem version, and stem offset were varied. When the ACPL was changed to 0, 3, and 6 mm in 20° extension, the maximum surface pressure was significantly increased for ACPL of 6 mm compared with 0 mm. Decreased stem anteversion resulted in a significant reduction in both the maximum and mean surface pressure compared with native anteversion from 20° extension to the neutral position. Increased stem offset resulted in significant increases in the maximum and mean surface pressure of the iliopsoas muscle compared with decreased stem offset in 20° extension. Not only large ACPL but also changes in stem version and offset affected the maximum surface pressure of the iliopsoas muscle.

Indexed as

Arthroplasty, Replacement, HipCadaverHumansMusclesProstheses and Implants

Identifiers

PMID36859708
PMCPMC9977861

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.