Evidence map›Paper›PMID 36859515›Full record

ReviewEye and vision (London, England)2023

Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma.

Iqbal Ike K Ahmed, Omar Sadruddin, Joseph F Panarelli

Open access · diamondAbstract readReview
In one paragraph

Review in Eye and vision (London, England), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 1 pooled it
4.5field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Management practices and surgical techniques for ab externo less invasive glaucoma surgery: a literature review and expert recommendations.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025
    Review
  8. Article
  9. Observational
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 2 countries.

Iqbal Ike K AhmedJohn Moran Eye Center, University of Utah, Salt Lake City, UT, USA.
Omar SadruddinSanten Inc, Emeryville, CA, USA.
Joseph F PanarelliNew York University, New York, NY, USA. joseph.panarelli@nyulangone.org.
New York University · USPrism Eye Institute · CASanten (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAlthough traditional surgical procedures for glaucoma (such as trabeculectomy and tube-shunt implantation) can significantly reduce intraocular pressure (IOP), they are associated with numerous complications, some of which are vision-threatening, or involve prolonged recovery or a highly intensive postoperative course. Micro-invasive glaucoma surgery (MIGS) procedures have shown better safety but reduced efficacy in achieving target IOP. Combinations of these methods have led to the development of subconjunctival micro-invasive procedures with safety comparable to traditional surgery and greater efficacy than minimally invasive methods. This review describes the use of one of these devices, the poly(styrene-block-isobutylene-block-styrene) (SIBS)-based PreserFlo MicroShunt (Santen, Emeryville, CA), in the surgical treatment of patients with glaucoma. MAIN TEXT: The MicroShunt is an 8.5-mm tube made of an inert polymer with no endplate, an internal diameter of 70 μm, and fins intended to prevent peritubular flow and anchor the device within the sclera to prevent proximal migration into the eye. Following ab externo implantation, the tube provides a conduit for flow of aqueous humor from the anterior chamber into the subconjunctival/sub-Tenon space. Clinical trials to date have shown that, when paired with mitomycin C (MMC) treatment, MicroShunt implantation significantly reduced both IOP and the number of glaucoma medications. These IOP-lowering results were found both when surgery was performed alone and with phacoemulsification. The MicroShunt also showed a safety profile comparable to that of traditional filtering surgery.

conclusionsThe MicroShunt and other novel subconjunctival procedures have shown substantial IOP reductions while mitigating hypotony-related complications. MMC, which modulates fibrosis and scarring postoperatively, is essential to surgical success. Randomized, long-term clinical trials will further clarify the role of controlled micro-incisional device-assisted ab externo glaucoma filtering surgery in long-term glaucoma management.

Indexed as

GlaucomaMicro-invasive glaucoma surgeryMicroShuntMitomycin C

Identifiers

PMID36859515
PMCPMC9979478
OpenAlexW4322753695

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.