Evidence map›Paper›PMID 36855914›Full record

ArticleOrthopaedic surgery2023

Stress Distribution of Different Pedicle Screw Insertion Techniques Following Single-Segment TLIF: A Finite Element Analysis Study.

Simengge Yang, Tianze Sun, Liwen Zhang, Menglin Cong, Anyun Guo, Dakai Liu, Mingzhi Song

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Risk factors for pedicle screw loosening: a comprehensive review.Journal of orthopaedic surgery and research · 2025
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Simengge YangDepartment of Orthopaedics, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
Tianze SunDepartment of Orthopaedics, The First Affiliated Hospital of Dalian Medical University, Dalian, China.ORCID https://orcid.org/0000-0002-6646-1040
Liwen ZhangDepartment of Orthopaedics, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
Menglin CongDepartment of Orthopedics, Qilu Hospital of Shandong University, Jinan, China.
Anyun GuoDepartment of Joint Trauma, General Hospital of Shenzhen University, Shenzhen, China.
Dakai LiuDepartment of Orthopaedics, The Second People's Hospital of Dalian, Dalian, China.ORCID https://orcid.org/0000-0002-6263-1022
Mingzhi SongDepartment of Orthopaedics, The First Affiliated Hospital of Dalian Medical University, Dalian, China.ORCID https://orcid.org/0000-0002-3184-4236
Dalian Medical University · CNCentral South University · CNQilu Hospital of Shandong University · CNSecond Affiliated Hospital of Dalian Medical University · CNShenzhen University · CN

Funding

National Natural Science Foundation of China 81973646The National Science Fund for Distinguished Young Scholars 82204822Young Innovative Talents Project of Guangdong General Universities 2019KQNCX124
6 · The paper itself

Abstract

objectivesAt present, a variety of posterior lumbar internal fixation implantation methods have been developed, which makes it difficult for spine surgeons to choose. The stress distribution of the internal fixation system is one of the important indexes to evaluate these technologies. Common insertion technologies include Roy Camille, Magerl, Krag, AO, and Weinstein insertion techniques. This study aimed to compare the distribution of von Mises stresses in different screw fixation systems established by these insertion technologies.

methodsHere, the three-dimensional finite element (FE) method was selected to evaluate the postoperative stress distribution of internal fixation. Following different pedicle screw insertion techniques, five single-segment transforaminal lumbar interbody fusion (TLIF) models were established after modeling and validation of the L1-S1 vertebrae FE model.

resultsBy analyzing the data, we found that stress concentration phenomenon was in all the models. Additionally, Roy-Camille, Krag, AO, and Weinstein insertion techniques led to the great stress on lumbar vertebra, intervertebral disc, and screw-rod fixation systems. Therefore, we hope that the results can provide ideas for clinical work and development of pedicle screws in the future. It is worth noting that flexion, unaffected side lateral bending, and affected side axial rotation should be limited for the patients with cages implanted.

conclusionsOverall, our method obtained the results that Magerl insertion technique was the relatively safe approach for pedicle screw implantation due to its relatively dispersive stress in TLIF models.

Indexed as

Fracture Fixation, InternalLumbar VertebraePedicle ScrewsSpinal FusionStress, MechanicalFinite Element AnalysisInternal FixatorsFinite Element AnalysisPedicle ScrewScrew and Rod SystemSpinal BiomechanicsStress

Identifiers

PMID36855914
PMCPMC10102325
OpenAlexW4322720040

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked