SynthesisKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023
Verasense sensor-assisted total knee arthroplasty showed no difference in range of motion, reoperation rate or functional outcomes when compared to manually balanced total knee arthroplasty: a systematic review.
Synthesis in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- A comparison on the clinical outcomes of using intraoperative load sensors versus manual balancing in total knee arthroplasty: a systematic review and meta-analysis.Journal of orthopaedic surgery and research · 2025Pooled it
- Robotic-assisted mechanically aligned total knee arthroplasty does not lead to better clinical and radiological outcomes when compared to conventional TKA: a systematic review and meta-analysis of randomized controlled trials.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Pooled it
- Postoperative outcomes after conventional, robotic-arm-assisted, and pressure-sensor-guided cruciate-retaining total knee arthroplasty: a retrospective cohort study.Journal of robotic surgery · 2026Article
- Sensor-guided robot-assisted TKA more precisely achieves targeted functional knee phenotypes than conventional robotic-assisted technique.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Article
- Inter- and Intra-Rater Reliability of Pre-Resection Ligament Tension Assessment Using a Digital Tensioner in Imageless Robotic-Assisted Total Knee Replacement.Orthopaedic surgery · 2026Article
- Alignment and/or ligament balancing? Towards truly personalized total knee arthroplasty-A narrative review.Journal of experimental orthopaedics · 2026Review
- Alignment Philosophies in Total Knee Arthroplasty: A Comprehensive Narrative Review.Arthroplasty today · 2026Article
- From empirical to analytical: Soft-tissue tension gauging in total knee arthroplasty.Knee surgery & related research · 2025Review
- Biosensor-Integrated Tibial Components in Total Knee Arthroplasty: A Narrative Review of Innovations, Challenges, and Translational Frontiers.Bioengineering (Basel, Switzerland) · 2025Review
- What Are the Game Changers in Total Knee Arthroplasty? A Narrative Review.Journal of personalized medicine · 2025Review
- Robotic evaluation of articular laxity (REAL) classification: a new intraoperative knee soft-tissue laxity classification using ROSA robotic software.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Article
- Functional preoperative assessment of coronal knee laxity better predicts postoperative patient outcomes than intraoperative surgeon-defined laxity in total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025Article
- Evaluation of serum vitamin D levels and their impact on functional outcomes among patients undergoing total knee arthroplasty.Bioinformation · 2025Article
- Navigated instrumentation and ligament tensioning device enhances initial gap acquisition during total knee arthroplasty procedure: A cadaveric study.Journal of experimental orthopaedics · 2025Article
- Do PROMs or Sensor-Based Monitoring Detect Improvements in Patients' Knee Function After Total-Knee Arthroplasty?-A Study Protocol for a Prospective Controlled Study.Sensors (Basel, Switzerland) · 2024Article
- No evidence of mid-flexion instability after robotic-assisted total knee arthroplasty as assessed by intraoperative pressure sensors.Arthroplasty (London, England) · 2024Article
- [Trends in navigation-handheld systems].Orthopadie (Heidelberg, Germany) · 2024Review
- Exploring the Performance of an Artificial Intelligence-Based Load Sensor for Total Knee Replacements.Sensors (Basel, Switzerland) · 2024Article
- The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty.Journal of orthopaedic surgery and research · 2023Article
- Definitions and consequences of current alignment techniques and phenotypes in total knee arthroplasty (TKA) - there is no winner yet.Journal of experimental orthopaedics · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe aim of this systematic review was to investigate the clinical and functional knee outcomes after Verasense sensor-assisted total knee arthroplasty (VA TKA), and to compare these outcomes, where possible, with those from manually balanced total knee arthroplasty (MB TKA).
methodsA systematic literature search following PRISMA guidelines was conducted on PubMed, Embase, Medline and Scopus from the beginning of January 2012 until the end of June 2022, to identify potentially relevant articles for this review. Selection was based on the following inclusion criteria: full text English- or German-language clinical studies, published in peer-reviewed journals, which assessed clinical and functional outcomes following VA TKA. Not original research, preprints, abstract-only papers, protocols, reviews, expert opinion papers, book chapters, surgical technique papers, and studies pertaining only to unicondylar knee arthroplasty (UKA) or patellofemoral arthroplasty (PFA) were excluded. Several scores (Knee Society Score [KSS], Oxford Knee Score [OKS], Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC], Knee injury and Osteoarthritis Outcome Score-4 subscales [KOOS4] and Physical Function-Computerised Adaptive Testing [PF-CAT]), alongside postoperative measurements of range of motion [ROM], reoperation rates and the rate of manipulation under anaesthesia [MUA]) were used to evaluate clinical and functional outcomes. The quality of included papers, except randomised control trials (RCTs), was evaluated using the Methodological Index for Non-Randomised Studies (MINORS). For the assessment of included RCTs, the Jadad Scale was used.
resultsThe literature search identified 243 articles. After removing duplicates, 184 papers were included in the initial screening process. Fourteen of them met all the inclusion criteria following the selection process. Mean MINORS for non-comparative studies value was 11.5 (11-12), and for comparative studies 18.2 (13-21). Mean Jadad Scale score was 3.6 (2-5). Outcomes from a total number of 3633 patients were evaluated (mean age at surgery 68.5 years [32-88 years]). In terms of clinical outcomes, the overwhelming majority of studies observed an improvement after VA TKA, but no statistically significant difference in ROM and reoperation rate when compared to MB TKA. On the other hand, lower rates of MUA have been described in the VA TKA group. An increase in postoperative clinical and functional scores values, when compared to the preoperative ones, has been reported in both groups, although no statistically significant difference between them has been observed.
conclusionThe use of Verasense pressure sensors in TKA leads to no significant improvement in ROM, reoperation rate or functional outcomes, when compared to the standard manually balancing technique. However, lower rates of MUA have been described in the VA TKA group. These findings highlight the importance of tools being able to measure ligament stresses or joint pressure for achieving an optimally balanced knee. LEVEL OF EVIDENCE: III.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.