Evidence map›Paper›PMID 36854769›Full record

ArticleScientific reports2023

Rapid diagnosis of membranous nephropathy based on serum and urine Raman spectroscopy combined with deep learning methods.

Xueqin Zhang, Xue Song, Wenjing Li, Cheng Chen, Miriban Wusiman, Li Zhang, Jiahui Zhang, Jinyu Lu, Chen Lu, Xiaoyi Lv

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
5.7field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Rapid profiling of carcinogenic types ofComputational and structural biotechnology journal · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 1 country.

Xueqin ZhangPeople's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, 830001, China.
Xue SongPeople's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, 830001, China.
Wenjing LiCollege of Software, Xinjiang University, Urumqi, 830046, China.
Cheng ChenCollege of Software, Xinjiang University, Urumqi, 830046, China.
Miriban WusimanXinjiang Medical University, Urumqi, 830054, China.
Li ZhangThe First Affiliated Hospital of Xinjiang Medical University, Urumqi, 830011, China.
Jiahui ZhangXinjiang Medical University, Urumqi, 830054, China.
Jinyu LuPeople's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, 830001, China.
Chen LuThe First Affiliated Hospital of Xinjiang Medical University, Urumqi, 830011, China. luchen670706@163.com.
Xiaoyi LvCollege of Software, Xinjiang University, Urumqi, 830046, China. xjuwawj01@163.com.
People's Hospital of Xinjiang Uygur Autonomous Region · CNXinjiang Medical University · CNXinjiang University · CNFirst Affiliated Hospital of Xinjiang Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Membranous nephropathy is the main cause of nephrotic syndrome, which has an insidious onset and may progress to end-stage renal disease with a high mortality rate, such as renal failure and uremia. At present, the diagnosis of membranous nephropathy mainly relies on the clinical manifestations of patients and pathological examination of kidney biopsy, which are expensive, time-consuming, and have certain chance and other disadvantages. Therefore, there is an urgent need to find a rapid, accurate and non-invasive diagnostic technique for the diagnosis of membranous nephropathy. In this study, Raman spectra of serum and urine were combined with deep learning methods to diagnose membranous nephropathy. After baseline correction and smoothing of the data, Gaussian white noise of different decibels was added to the training set for data amplification, and the amplified data were imported into ResNet, AlexNet and GoogleNet models to obtain the evaluation results of the models for membranous nephropathy. The experimental results showed that the three deep learning models achieved an accuracy of 1 for the classification of serum data of patients with membranous nephropathy and control group, and the discrimination of urine data was above 0.85, among which AlexNet was the best classification model for both samples. The above experimental results illustrate the great potential of serum- and urine-based Raman spectroscopy combined with deep learning methods for rapid and accurate identification of patients with membranous nephropathy.

Indexed as

Body FluidsDeep LearningGlomerulonephritis, MembranousKidney Failure, ChronicRenal InsufficiencyHumansSpectrum Analysis, Raman

Identifiers

PMID36854769
PMCPMC9974944
OpenAlexW4322619421

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.