Evidence map›Paper›PMID 36852488›Full record

ArticleJournal of medical radiation sciences2023

Assessment of scatter radiation dose received by comforters and carers during digital breast tomosynthesis mammography.

Michelle Kostidis, Joshua G Varcoe, Peter Barnes

Open access · goldAbstract read
In one paragraph

Article in Journal of medical radiation sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Michelle KostidisAustin Health, Repatriation Hospital Campus, 300 Waterdale Road, Heidelberg Heights, Victoria, Australia.ORCID https://orcid.org/0000-0002-0334-762X
Peter BarnesAustin Health, Repatriation Hospital Campus, 300 Waterdale Road, Heidelberg Heights, Victoria, Australia.
Heidelberg Repatriation Hospital · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionMammographic imaging can cause considerable stress and anxiety for some patients and may require someone to remain in the room during the procedure to provide both physical and emotional support. As such, these comforters and carers (C&C) are exposed to ionising radiation. Limited evidence is available stating the radiation dose received during a digital breast tomosynthesis (DBT) examination. This research aims to determine the optimal standing position for a C&C in the mammography room during a DBT mammogram that results in the lowest radiation dose, whilst providing high-quality imaging, care and comfort to the patient.

methodsA scatter detector was used to measure the dose at different standing positions of the carer relative to the patient during an examination. A polymethyl methacrylate (PMMA) phantom was also used to model the patient's breast and torso for further scatter dose measurements.

resultsThe median air kerma for craniocaudal views posterior to the patient is 0.75 μGy compared with 10.1 μGy to either side. The median air kerma for mediolateral oblique views for posterolateral position is 0.41 μGy compared with 2.6 μGy anterolateral. No significant effect from breast density is noted from the dataset.

conclusionThe optimal position for the C&C to stand is directly behind the patient in the craniocaudal position, and as far as possible posterolateral to the breast being imaged in the mediolateral oblique position. These two positions will result in the least radiation dose to the C&C.

Indexed as

Breast NeoplasmsCaregiversBreastBreast DensityFemaleHumansMammographyRadiation Dosagebreastcarersmammographyradiation dosescattered radiationtomosynthesis

Identifiers

PMID36852488
PMCPMC10258642
OpenAlexW4322617474

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.