ArticleAdvances in radiation oncology
Breathing-Adapted Imaging Techniques for Rapid 4-Dimensional Lung Tomosynthesis.
Article in Advances in radiation oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: This article presents enhancements to a 4-dimensional (4D) lung digital tomosynthesis (DTS) model introduced in a 2018 paper. That model was proposed as an adjunct to 4D computed tomography (4DCT) to improve tumor localization through artifact reduction achieved by imaging the entire lung in all projections, reducing the projection collection time duration for each phase compared with 4DCT, and requiring only a single-breath cycle to capture all phases. This is applicable to SABR treatment planning. Enhancements comprise customized patient 4D-DTS x-ray scanning parameters. Methods and Materials: Imaging parameters derived with the 4D-DTS model were arc duration, frames per second, pulse duration, and tube current normalized to single-chest radiographic milliampere-seconds (mA/mAs Results: 4D-DTS imaging techniques were customized to volunteer respiratory waveforms and sinusoidal waveforms. Technique settings at the highest velocity portions of the volunteer waveforms were arc duration 0.066 seconds, frame rate 921 Hz, pulse duration 1.076 ms, and normalized tube current 76.2 s Conclusions: 4D-DTS image technique settings can be customized to individual patient breathing patterns so that captured range of motion satisfies an operator-selected value.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.