Evidence map›Paper›PMID 36852145›Full record

ArticleJGH open : an open access journal of gastroenterology and hepatology2023

Effectiveness of adenosine triphosphate to monitor manual cleaning and disinfection efficacy of flexible endoscopes in Hong Kong.

Ada S F Chan, Henry L Y Chan, Bruno K L Yan, Mooris K C Lai

Open access · goldAbstract read
In one paragraph

Article in JGH open : an open access journal of gastroenterology and hepatology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 2 countries.

Ada S F ChanDepartment of Nursing Administration Union Hospital Hong Kong SAR China.ORCID https://orcid.org/0000-0003-1035-1632
Henry L Y ChanFaculty of Medicine The Chinese University of Hong Kong Hong Kong SAR China.
Bruno K L YanDepartment of Emergency Medicine Union Hospital Hong Kong SAR China.
Mooris K C LaiDepartment of Nursing Administration Union Hospital Hong Kong SAR China.
Union Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aim: Adenosine triphosphate (ATP) bioluminescence assay is widely adopted in the West to allow rapid evaluation of endoscopes for bacteriologic/biologic residue, but this practice is rarely adopted in Asia. In this continuous quality improvement program, we evaluated the utility of ATP in bacteriologic surveillance on endoscope reprocessing. Methods: A total of 456 samples (304 ATP samples and 152 culture samples) of 38 flexible endoscopes were assessed after routine clinical use in a private hospital in Hong Kong. Endoscopes were assessed with an ATP system and bacterial cultures at different time points during the reprocessing. Results: After pre-cleaning, the ATP values ranged from 228 to 65 163 relative light units (RLU) through all endoscope types. After manual cleaning, ATP values were decreased to 7-81 RLU (median, 19 RLU) for endoscope surface and 3-671 RLU (median, 12 RLU) for channel rinsate. There was a significant reduction in ATP levels between pre-cleaning and after manual cleaning. One of the 38 (2.6%) endoscopes (a duodenoscope) had an ATP value of 671 RLU from channel rinsate, which exceeded the benchmark for cleanliness of >200 RLU, and was sent back for re-cleaning. All endoscopes cultured no bacteria after high-level disinfection (HLD) by automated endoscope reprocessor (AER) and storage up to 24 h. ATP values were <200 RLU for all endoscopes after HLD and storage. Conclusions: Adenosine triphosphate bioluminescence assay offers a rapid, practical, and cost-effective alternative for detection of endoscope microbial residue as well as a routine monitoring tool for endoscope cleanliness in the clinical setting.

Indexed as

adenosine triphosphateautomated endoscope reprocessorflexible endoscopeshigh‐level disinfectionmanual cleaning

Identifiers

PMID36852145
PMCPMC9958339
OpenAlexW4319833075

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked