Reversed windshield-wiper effect leads to failure of cement-augmented pedicle screw: Biomechanical mechanism analysis by finite element experiment.

Zhong Wang, Peng Liu, Ming-Yong Liu, Xiang Yin, Yi-Bo Gan, Ke-Yu Luo, Liang Zhang, Jian-Hua Zhao, Qiang Zhou, Yao-Yao Liu

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 3 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Zhong WangDepartment of Orthopedics, The Third Affiliated Hospital of Chongqing Medical University, Chongqing, 401120, PR China.
Peng LiuDivision of Spine Surgery, Department of Orthopedics, Daping Hospital(Army Medical Center of PLA), Army Medical University, Chongqing, 400042, PR China.
Ming-Yong LiuDivision of Spine Surgery, Department of Orthopedics, Daping Hospital(Army Medical Center of PLA), Army Medical University, Chongqing, 400042, PR China.
Xiang YinDivision of Spine Surgery, Department of Orthopedics, Daping Hospital(Army Medical Center of PLA), Army Medical University, Chongqing, 400042, PR China.
Yi-Bo GanDivision of Spine Surgery, Department of Orthopedics, Daping Hospital(Army Medical Center of PLA), Army Medical University, Chongqing, 400042, PR China.
Ke-Yu LuoDivision of Spine Surgery, Department of Orthopedics, Daping Hospital(Army Medical Center of PLA), Army Medical University, Chongqing, 400042, PR China.
Liang ZhangDivision of Spine Surgery, Department of Orthopedics, Daping Hospital(Army Medical Center of PLA), Army Medical University, Chongqing, 400042, PR China.
Jian-Hua ZhaoDivision of Spine Surgery, Department of Orthopedics, Daping Hospital(Army Medical Center of PLA), Army Medical University, Chongqing, 400042, PR China.
Qiang ZhouDepartment of Orthopedics, The Third Affiliated Hospital of Chongqing Medical University, Chongqing, 401120, PR China.
Yao-Yao LiuDivision of Spine Surgery, Department of Orthopedics, Daping Hospital(Army Medical Center of PLA), Army Medical University, Chongqing, 400042, PR China.
Army Medical University · CNChongqing Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The failure mode of cement-augmented pedicle screw (CAPS) was different from common pedicle screw. No biomechanical study of this failure mode named as "reversed windshield-wiper effect" was reported. To investigate the mechanisms underlying this failure mode, a series of finite element models of CAPS and PS were modified on L4 osseous model. Nine models were created according to the cement volume at 0.5 mL interval (range: 1-5 mL). Pullout load and cranio-caudal loads were applied on the screws. Stress and instantaneous rotation center (IRC) of the vertebra were observed. Under cranio-caudal load, the stress concentrated on the screw tip and pedicle region. The maximal stress (MS) at the screw tip region was +2.143 MPa higher than pedicle region. With cement volume increasing, the maximal stress (MS) at the screw tip region decreased dramatically, while MS at pedicle region was not obviously affected. As dose increased to 1.5 mL, the MS at pedicle region became higher than screw tip region and the maximal stress difference was observed at 3.5 mL. IRC of the vertebra located at the facet joint region in PS model. While IRC in CAPS models shifted anteriorly closer to the vertebral body with the increasing of cement volume. Under axial pull-out load, the maximal stress (MS) of cancellous bone in CAPS models was 29.53-50.04% lower than that 2.228 MPa in PS model. MS in the screw-bone interface did not change significantly with cement volume increasing. Therefore, the possible mechanism is that anterior shift of IRC and the negative difference value of MS between screw tip and pedicle region due to cement augmentation, leading to the screw rotate around the cement-screw complex as the fulcrum point.

Indexed as

BiomechanicsCement augmentationFenestrated pedicle screwsFinite element analysisLumbar spineScrew loosening

Identifiers

PMID36852063
PMCPMC9957816
OpenAlexW4320922093

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.