Evidence map›Paper›PMID 36850937›Full record

ArticleSensors (Basel, Switzerland)2023

A Novel Method to Model Image Creation Based on Mammographic Sensors Performance Parameters: A Theoretical Study.

Nektarios Kalyvas, Anastasia Chamogeorgaki, Christos Michail, Aikaterini Skouroliakou, Panagiotis Liaparinos, Ioannis Valais, George Fountos, Ioannis Kandarakis

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nektarios KalyvasRadiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, University of West Attica, 122 10 Athens, Greece.ORCID 0000-0002-9251-9170
Anastasia ChamogeorgakiDepartment of Biomedical Engineering, University of West Attica, 122 10 Athens, Greece.
Christos MichailRadiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, University of West Attica, 122 10 Athens, Greece.ORCID 0000-0001-5863-8013
Aikaterini SkouroliakouDepartment of Biomedical Engineering, University of West Attica, 122 10 Athens, Greece.
Panagiotis LiaparinosRadiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, University of West Attica, 122 10 Athens, Greece.ORCID 0000-0003-3036-9389
Ioannis ValaisRadiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, University of West Attica, 122 10 Athens, Greece.ORCID 0000-0001-6808-0252
George FountosRadiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, University of West Attica, 122 10 Athens, Greece.
Ioannis KandarakisRadiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, University of West Attica, 122 10 Athens, Greece.

Funding

University of West Attica Not available, part of the paid APC cost may be reimbursed after application
6 · The paper itself

Abstract

backgroundMammographic digital imaging is based on X-ray sensors with solid image quality characteristics. These primarily include (a) a response curve that yields high contrast and image latitude, (b) a frequency response given by the Modulation Transfer Function (

methodsIn this work, a methodological approach is introduced and described for creating digital phantom images based on the measured image quality properties of the sensor. For this purpose, a mathematical phantom, simulating breast tissue and lesions of blood, adipose, muscle, Ca and Ca(50%)-P(50%) was created by considering the corresponding X-ray attenuation coefficients. The simulated irradiation conditions of the phantom used four mammographic spectra assuming exponential attenuation. Published data regarding noise and blur of a commercial RadEye HR CMOS imaging sensor were used as input data for the resulting images.

resultsIt was found that the Ca and Ca(50%)-P(50%) lesions were visible in all exposure conditions. In addition, the W/Rh spectrum at 28 kVp provided more detailed images than the corresponding Mo/Mo spectrum.

conclusionsThe presented methodology can act complementarily to image quality measurements, leading to initial optimization of the X-ray exposure parameters per clinical condition.

Indexed as

AdiposityMammographyModels, TheoreticalMusclesPhantoms, Imagingdigital phantommammographyRadeye sensorradiation detectorssimulated image

Identifiers

PMID36850937
PMCPMC9968010

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.