Evidence map›Paper›PMID 36850933›Full record

ArticleSensors (Basel, Switzerland)2023

Spectroradiometer Calibration for Radiance Transfer Measurements.

Clemens Rammeloo, Andreas Baumgartner

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Clemens RammelooGerman Aerospace Center (DLR), Remote Sensing Technology Institute (IMF), 82234 Weßling, Germany.ORCID 0000-0003-2454-1306
Andreas BaumgartnerGerman Aerospace Center (DLR), Remote Sensing Technology Institute (IMF), 82234 Weßling, Germany.ORCID 0000-0002-8495-5407

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optical remote sensing and Earth observation instruments rely on precise radiometric calibrations which are generally provided by the broadband emission from large-aperture integrating spheres. The link between the integrating sphere radiance and an SI-traceable radiance standard is made by spectroradiometer measurements. In this work, the calibration efforts of a Spectra Vista Corporation (SVC) HR-1024i spectroradiometer are presented to study how these enable radiance transfer measurements at the Calibration Home Base (CHB) for imaging spectrometers at the Remote Sensing Technology Institute (IMF) of the German Aerospace Center (DLR). The spectral and radiometric response calibrations of an SVC HR-1024i spectroradiometer are reported, as well as the measurements of non-linearity and its sensitivity to temperature changes and polarized light. This achieves radiance transfer measurements with the calibrated spectroradiometer with relative expanded uncertainties between 1% and 3% (k=2) over the wavelength range of 380 nm to 2500 nm, which are limited by the uncertainties of the applied radiance standard.

Indexed as

polarization sensitivityradiance transferradiometric calibrationspectral calibrationspectrometerSVC HR-1024itemperature sensitivity

Identifiers

PMID36850933
PMCPMC9959733

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.