Evidence map›Paper›PMID 36850806›Full record

ArticleSensors (Basel, Switzerland)2023

Comparison of Three Motion Capture-Based Algorithms for Spatiotemporal Gait Characteristics: How Do Algorithms Affect Accuracy and Precision of Clinical Outcomes?

Amélie Caron-Laramée, Roua Walha, Patrick Boissy, Nathaly Gaudreault, Nikola Zelovic, Karina Lebel

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Gait analysis methods in people with spinal cord injury: a systematic review.Journal of neuroengineering and rehabilitation · 2026
    Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Amélie Caron-LaraméeDépartement de Génie Électrique et de Génie Informatique, Faculté de Génie, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada.
Roua WalhaDepartment of Surgery, Orthopedics Division, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, QC J1H 5N4, Canada.
Patrick BoissyDepartment of Surgery, Orthopedics Division, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, QC J1H 5N4, Canada.ORCID 0000-0001-6582-4519
Nathaly GaudreaultSchool of Rehabilitation, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, QC J1H 5N4, Canada.
Nikola ZelovicDépartement de Génie Électrique et de Génie Informatique, Faculté de Génie, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada.ORCID 0000-0002-9144-9772
Karina LebelDépartement de Génie Électrique et de Génie Informatique, Faculté de Génie, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada.

Funding

Canada Research Chairs 950-232481
6 · The paper itself

Abstract

Gait assessment is of interest to clinicians and researchers because it provides information about patients' functional mobility. Optoelectronic camera-based systems with gait event detection algorithms are considered the gold standard for gait assessment. Yet, the choice of the algorithm used to process data and extract the desired parameters from those detected gait events has an impact on the validity and reliability of the gait parameters computed. There are multiple techniques documented in the literature for computing gait events, including the analysis of the minimal position of the heel and toe markers, the computation of the relative distance between sacrum and foot markers, and the assessment of the smallest distance between the heel and toe markers. Validation studies conducted on these algorithms report variations in accuracy. Yet, these studies were conducted in different conditions, at varying gait velocities, and on different populations. The purpose of this study is to compare accuracy, precision, and robustness of three algorithms using motion capture data obtained from 25 healthy persons and 21 psoriatic arthritic patients walking at three distinct speeds on an instrumented treadmill. Errors in gait events recognition (heel strike-HS and toe-off-TO) and their impact on gait metrics (stance phase and stride length) are reported and compared to ground reaction force events measured with force plates. Over the 9114 collected steps across all walking speeds, more than 99% of gait events were recognized by all algorithms. On average, HS events were detected within 1.2 ms of the reference for two algorithms, while the third one detected HS late, with an average detection error of 40.7 ms. Yet, significant variations in accuracy were noted with gait speed; the performance decreased for all algorithms at slow speed. TO events were identified early by all algorithms, with an average error ranging from 16.0 to 100.0 ms. These gait events errors lead to 2-15% inaccuracies in stance phase assessment, while the impact on stride length remains below 0.3 cm. Overall, the algorithm based on the relative distance between the sacral and foot markers stood out for its accuracy, precision, and robustness at all walking speeds.

Indexed as

GaitMotion CaptureAlgorithmsHumansReproducibility of ResultsWalking Speedaccuracyalgorithmscamera-based motion captureforce platesgait event detection

Identifiers

PMID36850806
PMCPMC9965262

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.