Evidence map›Paper›PMID 36850796›Full record

ArticleSensors (Basel, Switzerland)2023

MA-RTI: Design and Evaluation of a Real-World Multipath-Assisted Device-Free Localization System.

Marco Cimdins, Sven Ole Schmidt, Fabian John, Manfred Constapel, Horst Hellbrück

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Marco CimdinsDepartment of Electrical Engineering and Computer Science, Technische Hochschule Lübeck, Mönkhofer Weg 239, 23562 Lübeck, Germany.ORCID 0000-0002-0114-5661
Sven Ole SchmidtDepartment of Electrical Engineering and Computer Science, Technische Hochschule Lübeck, Mönkhofer Weg 239, 23562 Lübeck, Germany.ORCID 0000-0001-7653-1463
Fabian JohnDepartment of Electrical Engineering and Computer Science, Technische Hochschule Lübeck, Mönkhofer Weg 239, 23562 Lübeck, Germany.ORCID 0000-0002-7009-0924
Manfred ConstapelFraunhofer Center for Maritime Logistics and Services, Blohmstraße 32, 21079 Hamburg, Germany.ORCID 0000-0002-7015-6778
Horst HellbrückDepartment of Electrical Engineering and Computer Science, Technische Hochschule Lübeck, Mönkhofer Weg 239, 23562 Lübeck, Germany.ORCID 0000-0001-7619-8015

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Device-free localization (DFL) systems exploit changes in the radio frequency channel by measuring, for example, the channel impulse response (CIR), to detect and localize obstacles within a target area. However, due to a lack of well-defined interfaces, missing modularization, as well as complex system configuration, it is difficult to deploy DFL systems outside of laboratory setups. This paper focused on the system view and the challenges that come with setting up a DFL system in an indoor environment. We propose MA-RTI, a modular DFL system that is easy to set up, and which utilizes a multipath-assisted (MA) radio-tomographic imaging (RTI) algorithm. To achieve a modular DFL system, we proposed and implemented an architectural model for DFL systems. For minimizing the configuration overhead, we applied a 3D spatial model, that helps in placing the sensors and calculating the required calibration parameters. Therefore, we configured the system solely with idle measurements and a 3D spatial model. We deployed such a DFL system and evaluated it in a real-world office environment with four sensor nodes. The radio technology was ultra-wideband (UWB) and the corresponding signal measurements were CIRs. The DFL system operated with CIRs that provided a sub-nanosecond time-domain resolution. After pre-processing, the update rate was approximately 46 Hz and it provided a localization accuracy of 1.0 m in 50% of all cases and 1.8 m in 80% of all cases. MA fingerprinting approaches lead to higher localization accuracy, but require a labor-intensive training phase.

Indexed as

channel impulse responsedevice-free localizationMQTTmultipath-assistedmultipath componentsradio tomographic imagingraytracingsystem architectureultra-wideband

Identifiers

PMID36850796
PMCPMC9962819

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.