ArticleSensors (Basel, Switzerland)2023
Thermal Calibration of Triaxial Accelerometer for Tilt Measurement.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- The Effect of Time Pressure on the Quality of Fillings and Arousal Levels of Dentists.Clinical and experimental dental research · 2025Trial
- On-Ground Calibration of a Nano-G Accelerometer for Micro-Vibration Monitoring in Space on a Dual-Axis Indexing Device.Sensors (Basel, Switzerland) · 2025Article
- Temperature Hysteresis Calibration Method of MEMS Accelerometer.Sensors (Basel, Switzerland) · 2025Article
- Structural Monitoring Without a Budget-Laboratory Results and Field Report on the Use of Low-Cost Acceleration Sensors.Sensors (Basel, Switzerland) · 2025Article
- Study on Spatiotemporal Variation in Internal Temperature Field in Quartz Flexible Accelerometer.Micromachines · 2025Article
- Thermal calibration for triaxial gyroscope of MEMS-IMU based on segmented systematic method.Scientific reports · 2024Article
- Combined Temperature Compensation Method for Closed-Loop Microelectromechanical System Capacitive Accelerometer.Micromachines · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The application of MEMS accelerometers used to measure inclination is constrained by their temperature dependence, and each accelerometer needs to be calibrated individually to increase stability and accuracy. This paper presents a calibration and thermal compensation method for triaxial accelerometers that aims to minimize cost and processing time while maintaining high accuracy. First, the number of positions to perform the calibration procedure is optimized based on the Levenberg-Marquardt algorithm, and then, based on this optimized calibration number, thermal compensation is performed based on the least squares method, which is necessary for environments with large temperature variations, since calibration parameters change at different temperatures. The calibration procedures and algorithms were experimentally validated on marketed accelerometers. Based on the optimized calibration method, the calibrated results achieved nearly 100 times improvement. Thermal drift calibration experiments on the triaxial accelerometer show that the thermal compensation scheme in this paper can effectively reduce drift in the temperature range of -40 °C to 60 °C. The temperature drifts of x- and y-axes are reduced from -13.2 and 11.8 mg to -0.9 and -1.1 mg, respectively. The z-axis temperature drift is reduced from -17.9 to 1.8 mg. We have conducted various experiments on the proposed calibration method and demonstrated its capacity to calibrate the sensor frame error model (SFEM) parameters. This research proposes a new low-cost and efficient strategy for increasing the practical applicability of triaxial accelerometers.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.