Evidence map›Paper›PMID 36850630›Full record

ArticleSensors (Basel, Switzerland)2023

On the Role of Training Data for SVM-Based Microwave Brain Stroke Detection and Classification.

Tomas Pokorny, Jan Vrba, Ondrej Fiser, David Vrba, Tomas Drizdal, Marek Novak, Luca Tosi, Alessandro Polo, Marco Salucci

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Tomas PokornyDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 166 00 Prague, Czech Republic.ORCID 0000-0001-7628-6031
Jan VrbaDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 166 00 Prague, Czech Republic.ORCID 0000-0001-6528-0187
Ondrej FiserDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 166 00 Prague, Czech Republic.ORCID 0000-0001-8259-0611
David VrbaDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 166 00 Prague, Czech Republic.ORCID 0000-0002-8631-4283
Tomas DrizdalDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 166 00 Prague, Czech Republic.ORCID 0000-0001-9061-8231
Marek NovakDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 166 00 Prague, Czech Republic.ORCID 0000-0001-9255-2651
Luca TosiELEDIA Research Center (ELEDIA@UniTN-University of Trento), DICAM-Department of Civil, Environmental, and Mechanical Engineering, Via Mesiano 77, 38123 Trento, Italy.ORCID 0000-0003-2089-2483
Alessandro PoloELEDIA Research Center (ELEDIA@UniTN-University of Trento), DICAM-Department of Civil, Environmental, and Mechanical Engineering, Via Mesiano 77, 38123 Trento, Italy.
Marco SalucciELEDIA Research Center (ELEDIA@UniTN-University of Trento), DICAM-Department of Civil, Environmental, and Mechanical Engineering, Via Mesiano 77, 38123 Trento, Italy.ORCID 0000-0002-6948-8636

Funding

Czech Science Foundation 21-00579SCzech Technical University in Prague SGS19/204/OHK4/3T/17
6 · The paper itself

Abstract

The aim of this work was to test microwave brain stroke detection and classification using support vector machines (SVMs). We tested how the nature and variability of training data and system parameters impact the achieved classification accuracy. Using experimentally verified numerical models, a large database of synthetic training and test data was created. The models consist of an antenna array surrounding reconfigurable geometrically and dielectrically realistic human head phantoms with virtually inserted strokes of arbitrary size, and different dielectric parameters in different positions. The generated synthetic data sets were used to test four different hypotheses, regarding the appropriate parameters of the training dataset, the appropriate frequency range and the number of frequency points, as well as the level of subject variability to reach the highest SVM classification accuracy. The results indicate that the SVM algorithm is able to detect the presence of the stroke and classify it (i.e., ischemic or hemorrhagic) even when trained with single-frequency data. Moreover, it is shown that data of subjects with smaller strokes appear to be the most suitable for training accurate SVM predictors with high generalization capabilities. Finally, the datasets created for this study are made available to the community for testing and developing their own algorithms.

Indexed as

MicrowavesStrokeAlgorithmsBrainHumansSupport Vector Machinebrain strokemicrowave devicesnumerical modelSVM

Identifiers

PMID36850630
PMCPMC9962620

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.