Damped Cantilever Microprobes for High-Speed Contact Metrology with 3D Surface Topography.

Michael Fahrbach, Min Xu, Wilson Ombati Nyang'au, Oleg Domanov, Christian H Schwalb, Zhi Li, Christian Kuhlmann, Uwe Brand, Erwin Peiner

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Michael FahrbachInstitute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Straße 66, 38106 Braunschweig, Germany.ORCID 0000-0003-1027-9968
Min XuPhysikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany.ORCID 0000-0002-5115-5737
Wilson Ombati Nyang'auInstitute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Straße 66, 38106 Braunschweig, Germany.ORCID 0000-0002-3927-2439
Oleg DomanovGETec Microscopy GmbH, Am Heumarkt 13, 1030 Vienna, Austria.ORCID 0000-0002-5127-4496
Christian H SchwalbGETec Microscopy GmbH, Am Heumarkt 13, 1030 Vienna, Austria.ORCID 0000-0003-2730-8059
Zhi LiPhysikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany.ORCID 0000-0002-7931-2992
Christian KuhlmannPhysikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany.
Uwe BrandPhysikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany.ORCID 0000-0002-4293-4982
Erwin PeinerInstitute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Straße 66, 38106 Braunschweig, Germany.ORCID 0000-0001-5801-813X

Funding

EMPIR 17IND05 MicroProbes and 19ENG05 NanoWires
6 · The paper itself

Abstract

We addressed the coating 5 mm-long cantilever microprobes with a viscoelastic material, which was intended to considerably extend the range of the traverse speed during the measurements of the 3D surface topography by damping contact-induced oscillations. The damping material was composed of epoxy glue, isopropyl alcohol, and glycerol, and its deposition onto the cantilever is described, as well as the tests of the completed cantilevers under free-oscillating conditions and in contact during scanning on a rough surface. The amplitude and phase of the cantilever's fundamental out-of-plane oscillation mode was investigated vs. the damping layer thickness, which was set via repeated coating steps. The resonance frequency and quality factor decreased with the increasing thickness of the damping layer for both the free-oscillating and in-contact scanning operation mode, as expected from viscoelastic theory. A very low storage modulus of E'≈100kPa, a loss modulus of E″≈434kPa, and a density of ρ≈1.2gcm-3 were yielded for the damping composite. Almost critical damping was observed with an approximately 130 µm-thick damping layer in the free-oscillating case, which was effective at suppressing the ringing behavior during the high-speed in-contact probing of the rough surface topography.

Indexed as

contact modehigh-throughput metrologypiezoresistive cantileverquality factorresonance frequencytactile surface scanning

Identifiers

PMID36850600
PMCPMC9967852

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.