Evidence map›Paper›PMID 36850441›Full record

ArticleSensors (Basel, Switzerland)2023

A Novel Tactile Function Assessment Using a Miniature Tactile Stimulator.

Chung-Tung Sung, Yung-Jung Wang, Jian-Jia Huang, Yu-Cheng Pei, Lei-Chi Lin, Wen-Hsin Mai, Bao-Luen Chang

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Chung-Tung SungDepartment of Medical Education, Chang Gung Memorial Hospital at Linkou Medical Center, Taoyuan 33305, Taiwan.
Yung-Jung WangDepartment of Medical Education, Chang Gung Memorial Hospital at Linkou Medical Center, Taoyuan 33305, Taiwan.
Jian-Jia HuangDepartment of Physical Medicine and Rehabilitation, Chang Gung Memorial Hospital at Linkou Medical Center, Taoyuan 33305, Taiwan.ORCID 0000-0002-9796-9744
Yu-Cheng PeiSchool of Medicine, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
Lei-Chi LinSchool of Medicine, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
Wen-Hsin MaiSchool of Chinese Medicine, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
Bao-Luen ChangSchool of Medicine, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.ORCID 0000-0002-4547-6155
Chang Gung University · TW

Funding

Chang Gung Memorial Hospital BMRPJ26Chang Gung Memorial Hospital CMRPG3C0461-4Chang Gung Memorial Hospital CMRPG3K0231-2Chang Gung Memorial Hospital CMRPG3K1021Chang Gung Memorial Hospital CMRPG3L0661-2Chang Gung Memorial Hospital CMRPG3M0021Taiwan Ministry of Science and Technology NSC 102-2314-B-182-012
6 · The paper itself

Abstract

Several methods for the measurement of tactile acuity have been devised previously, but unexpected nonspatial cues and intensive manual skill requirements compromise measurement accuracy. Therefore, we must urgently develop an automated, accurate, and noninvasive method for assessing tactile acuity. The present study develops a novel method applying a robotic tactile stimulator to automatically measure tactile acuity that comprises eye-opened, eye-closed training, and testing sessions. Healthy participants judge the orientation of a rotating grating ball presented on their index fingerpads in a two-alternative forced-choice task. A variable rotation speed of 5, 10, 40, or 160 mm/s was used for the tactile measurement at a variety of difficulties. All participants met the passing criteria for the training experiment. Performance in orientation identification, quantified by the proportion of trials with correct answers, differed across scanning directions, with the highest rotation speed (160 mm/s) having the worst performance. Accuracy did not differ between vertical and horizontal orientations. Our results demonstrated the utility of the pre-test training protocol and the functionality of the developed procedure for tactile acuity assessment. The novel protocol performed well when applied to the participants. Future studies will be conducted to apply this method to patients with impairment of light touch.

Indexed as

CuesRoboticsHealthy VolunteersHumansRotationautomatedgrating ballminiaturerobotictactiletactile acuitytactile stimulator

Identifiers

PMID36850441
PMCPMC9966508
OpenAlexW4319601796

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.